Peakmeter 11528G Series
Page 5-6 Getting started
5.10.2. Key functions (10220, 11280)
When inserting 11528G peakmeters (serial-no. 1500 and above) into the
units the switches on the rear side change their functions. These are then
as follows:
Voltage selector:
Has to be set to actual mains voltage.
Disconnect mains before switching! Use the
correct fuse value as defined!
220 - 240 V AC operation: 63 mA slow blow
110 - 120 V AC operation: 125 mA slow blow
PH man switch:
Switches the 10 ms only mode
FAST switch:
Switches between standard and fast integration time.
CAL switch:
Activates resp. deactivates the highlighted headroom
control.
RES switch:
Switches to spot/peak hold mode.
This switch is only active when its function is
featured by the instrument inserted!