background image

3

It’s Under Control

®

Read Instructions.

 Read all safety and operating instructions before operating the unit.

Retain Instructions.

 Keep the safety and operating instructions for future reference.

Heed Warnings.

 Adhere to all warnings on the unit and in the operating instructions.

Follow Instructions.

 Install and operate in accordance with the manufacturer’s 

instructions.

Accessories. 

Only use attachments/accessories specified by the manufacturer.

Portable Cart Warning.

 Use only with the cart, stand, tripod, bracket, or table specified 

by the manufacturer, or sold with the apparatus. When a cart is used, use caution when 

moving the cart/apparatus combination to avoid injury from tip-over.

Heat.

 Do not block any ventilation openings.

Heat.

 Keep the unit away from heat sources such as radiators, heat registers, stoves, etc., 

including amplifiers that produce heat.

Power.

 Unplug this apparatus during lightning storms or when unused 

for long periods of time.

Power Sources.

 Connect only to the power cord that was included with 

the unit.

Power Cord Protection.

 Route power supply cords so that they are 

not likely to be walked on or pinched by items placed on or against them, paying particular 

attention to the cords at plugs, at convenient receptacles, and at the point at which they 

exit from the unit.

Power Cord Grounding Plug.

 Do not remove the grounding prong of the grounding-type 

plug. A grounding type plug has two blades and a third grounding prong. The third prong 

is provided for your safety. If the provided plug does not fit into your outlet, consult an 

electrician for replacement of the obsolete outlet.

MAINS Outlet.

 Where MAINS outlets are used, the apparatus shall be connected to a 

MAINS socket outlet with a protective earthing connection.

MAINS Plug.

 Where the MAINS plug or an appliance coupler is used as the disconnect 

device, the disconnect device shall remain readily operable.

Water and Moisture.

 Do not use the unit near water—for example, near a sink, in a wet 

basement, near a swimming pool, near an open window, etc.

Object and Liquid Entry.

 Do not allow objects to fall or liquids to be spilled into the 

enclosure through openings.

Cleaning.

 Clean only with dry cloth.

Servicing.

 Do not attempt any service beyond that described in the operating instructions. 

Refer all other service needs to qualified service personnel.

SAFETY SUGGESTIONS

WARNING!

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 

EXPOSE THE UNIT TO RAIN OR MOISTURE.

Damage Requiring Service.

 The unit should be serviced by qualified service personnel 

when:

    Objects have fallen or liquid has been spilled into the unit.
    The power supply cord or the plug has been damaged.
 

  The unit does not appear to operate normally or exhibits a marked change in 

performance.

    The unit has been dropped or the enclosure has been damaged.

Содержание VXP-82

Страница 1: ...1 It s Under Control Installation and Operation Guide 70 210210 13 V1 1 It s Under Control VXP 82 VXP 82 All in one Presentation System...

Страница 2: ...the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for he...

Страница 3: ...Cord Grounding Plug Do not remove the grounding prong of the grounding type plug A grounding type plug has two blades and a third grounding prong The third prong is provided for your safety If the pr...

Страница 4: ...ial and workmanship in this product The following are not covered by the warranty Damage resulting from 1 Accident misuse abuse or neglect 2 Failure to follow instructions contained in this Guide 3 Re...

Страница 5: ...apter 1 Welcome 7 Important Notes 8 Product Contents 8 Chapter 2 Features and Description 9 Front Panel 10 Rear Panel 11 Pinout 14 Chapter 3 Installation and Operation 15 Wiring and Connections 15 Web...

Страница 6: ...All in One Presentation System VXP 82 6...

Страница 7: ...unit With support for multiple AV inputs and outputs built in control and HDBaseT communication the VXP 82 enables presentations in two rooms simultaneously The VXP 82 8x2 multi format matrix switch...

Страница 8: ...carrier immediately Report any equipment malfunctions to RTI or an authorized RTI distributor IMPORTANT NOTES Please read these important notes about the VXP 82 The VXP 82 should be placed in an area...

Страница 9: ...rs in addition to Ethernet IR and RS 232 pass through Supports Auto CEC control set through driver commands or Web UI Bi directional KVM functionality for HDMI or HDBaseT outputs Ideal for presentatio...

Страница 10: ...on Press to select VGA IN5 source as input 8 VGA IN6 Selection Press to select VGA IN6 source as input 9 HDBT IN7 Selection Press to select HDBT IN7 source as input 10 HDBT IN8 Selection Press to sele...

Страница 11: ...control system separate if needed G LAN Connect to an Ethernet network to enable telnet or web UI Control H RTI COM Connect to a ZM 24 Zigbee transceiver module for two way communication with RTI hand...

Страница 12: ...for external devices such as IR or RF receivers Internally tied to power jack S GROUND Ground connection for devices connected to 12VDC SIGNAL IN or HIGH OUT terminals T SIGNAL IN Used to connect to a...

Страница 13: ...C HDMI OUT Connect to an HDMI display D HDBT OUT Connect to VXP R HDBaseT Extender or compatible HDBaseT receiver via a Cat 5e 6 7 cable E FW PORT Service use only F SCALER Service use only G HDMI HD...

Страница 14: ...N cables DB 9 Pin Signal Signal Name Description 1 DCD Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set Ready 7 RTS Request To Send 8...

Страница 15: ...ect USB devices to USB DEVICE ports See USB Configuration Notes below 7 One way PoE enables the switcher to power the remote HDBaseT receiver along a single Cat cable 8 Power on all attached devices N...

Страница 16: ...er SET POWER STATUS HDCP LINK Model VXP R HDBaseT Extender Receiver RS232 HDBT IN HDMI OUT IR IN IR OUT S PDIF IN S PDIF OUT DC 12V TX RX ETHERNET AUDIO OUT USB HOST USB DEVICE Ethernet Switch Etherne...

Страница 17: ...ay 3 Enter the default password admin and click Login Web UI Introduction The Web UI main page includes several tabs for basic and advanced settings including Video Control Audio Control Configuration...

Страница 18: ...n white to green to select the audio input for the output By default De EMBED IN1 routes to AUDIO OUT1 and HDMI OUT DE EMBED IN2 routes to AUDIO OUT2 and HDBT OUT De embedded Audio of HDMI OUT De embe...

Страница 19: ...io input Mute Click to mute unmute audio output By default the volume of MIC LINE audio input is 0dB CONFIGURATION 1 Input HDCP This section allows you to enable or disable HDCP capability of each inp...

Страница 20: ...tting of each input port CHAPTER 3 INSTALLATION AND OPERATION Apply Click to enable the EDID setting To set up the EDID setting for HDMI IN1 Go to the HDMI IN1 and select the settings from its drop do...

Страница 21: ...utomatically when there s no signal at the display for 3 minutes By default CEC Auto Control is set to ON 4 Output Resolution Configure EDID setting of each input port Set the scaler for HDMI OUT and...

Страница 22: ...default KEY LOCK is set as OFF 2 Network Network is used to set between the dynamic and static IP address DHCP When enabled the IP address of the Matrix is assigned automatically by the DHCP server co...

Страница 23: ...pgrade This section allows you to upgrade the Web UI To update the Web UI 1 Click Browse for the update bin file 2 Then click Upgrade to proceed 5 System This section allows you to reboot or reset the...

Страница 24: ...ctory defaults Click Factory Reset and then click OK in the pop up window Then wait 30 seconds to refresh and re login the Web UI CHAPTER 3 INSTALLATION AND OPERATION 6 Firmware Version This section a...

Страница 25: ...maximum per port adjustable 200mA maximum high IR output port IR Frequency Transmission Range 15kHz 460kHz Trigger Outputs Three 12 VDC 100mA max each Relays Three 30VDC 5 Amps Sense Inputs Three 3 24...

Страница 26: ...eT PoH RJ45 Resolution Range 800 x 600 60Hz to 4K x 2K 60Hz HDBaseT Transmission Distance 1080p 60Hz 100m 4K x 2K 60Hz 90m Switching Seamless EDID Management Built in EDID data and manual EDID managem...

Страница 27: ...s or have a question about your RTI product please contact RTI Technical Support for assistance see the Contacting RTI section of this guide for contact details RTI provides technical support by telep...

Страница 28: ...on System VXP 82 28 Remote Technologies Incorporated 5775 12th Avenue East Suite 180 Shakopee MN 55379 Tel 952 253 3100 Fax 952 253 3131 www rticorp com 2019 Remote Technologies Inc All rights reserve...

Отзывы: