background image

13

It’s Under Control

®

CHAPTER 2  |  FEATURES AND DESCRIPTION

VXP-82 REAR PANEL DESCRIPTION 

No. Name

Function

A

RS-232 PORTS 1-2

RJ-45 output ports for RS-232 communication using 

Cat-5 cable. The VXP-82 ships with two RJ-45 (female) 

to DB-9 (male) adapters.

NOTE: RS-232 communication cabling should be limited 

to 50 feet (16m) depending on baud rate. 

See Pinout section.

B

MPIO PORTS 1-6

Each port is compatible with industry standard IR 

emitters and IR repeating systems. Each output port is 

capable of driving up to four IR emitters directly. 

C

HDMI OUT

Connect to an HDMI display.

D

HDBT OUT

Connect to VXP-R HDBaseT Extender or compatible 

HDBaseT receiver via a Cat 5e/6/7 cable.

E

FW PORT

Service use only.

F

SCALER

Service use only.

G

HDMI/HDBT SWITCH

Service use only.

H

VIDEO RESET

Use a pointed stylus to hold down the RESET button 

for three or more seconds, and then release it to reset 

VXP-82 video matrix only

.

I

AUDIO OUT 1-2

De-embedded audio outputs from the selected video 

source. Connect to audio system such as an amplifier. 

Factory default: Audio Port 1 assigned to HDMI output 

and Port 2 assigned to HDBaseT output. Audio Ports can 

be used interchangeably with any inputs, configured via 

the web interface or driver commands.

See Pinout section.

B

C

D

E

F

G

H

I

A

Содержание VXP-82

Страница 1: ...1 It s Under Control Installation and Operation Guide 70 210210 13 V1 1 It s Under Control VXP 82 VXP 82 All in one Presentation System...

Страница 2: ...the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for he...

Страница 3: ...Cord Grounding Plug Do not remove the grounding prong of the grounding type plug A grounding type plug has two blades and a third grounding prong The third prong is provided for your safety If the pr...

Страница 4: ...ial and workmanship in this product The following are not covered by the warranty Damage resulting from 1 Accident misuse abuse or neglect 2 Failure to follow instructions contained in this Guide 3 Re...

Страница 5: ...apter 1 Welcome 7 Important Notes 8 Product Contents 8 Chapter 2 Features and Description 9 Front Panel 10 Rear Panel 11 Pinout 14 Chapter 3 Installation and Operation 15 Wiring and Connections 15 Web...

Страница 6: ...All in One Presentation System VXP 82 6...

Страница 7: ...unit With support for multiple AV inputs and outputs built in control and HDBaseT communication the VXP 82 enables presentations in two rooms simultaneously The VXP 82 8x2 multi format matrix switch...

Страница 8: ...carrier immediately Report any equipment malfunctions to RTI or an authorized RTI distributor IMPORTANT NOTES Please read these important notes about the VXP 82 The VXP 82 should be placed in an area...

Страница 9: ...rs in addition to Ethernet IR and RS 232 pass through Supports Auto CEC control set through driver commands or Web UI Bi directional KVM functionality for HDMI or HDBaseT outputs Ideal for presentatio...

Страница 10: ...on Press to select VGA IN5 source as input 8 VGA IN6 Selection Press to select VGA IN6 source as input 9 HDBT IN7 Selection Press to select HDBT IN7 source as input 10 HDBT IN8 Selection Press to sele...

Страница 11: ...control system separate if needed G LAN Connect to an Ethernet network to enable telnet or web UI Control H RTI COM Connect to a ZM 24 Zigbee transceiver module for two way communication with RTI hand...

Страница 12: ...for external devices such as IR or RF receivers Internally tied to power jack S GROUND Ground connection for devices connected to 12VDC SIGNAL IN or HIGH OUT terminals T SIGNAL IN Used to connect to a...

Страница 13: ...C HDMI OUT Connect to an HDMI display D HDBT OUT Connect to VXP R HDBaseT Extender or compatible HDBaseT receiver via a Cat 5e 6 7 cable E FW PORT Service use only F SCALER Service use only G HDMI HD...

Страница 14: ...N cables DB 9 Pin Signal Signal Name Description 1 DCD Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set Ready 7 RTS Request To Send 8...

Страница 15: ...ect USB devices to USB DEVICE ports See USB Configuration Notes below 7 One way PoE enables the switcher to power the remote HDBaseT receiver along a single Cat cable 8 Power on all attached devices N...

Страница 16: ...er SET POWER STATUS HDCP LINK Model VXP R HDBaseT Extender Receiver RS232 HDBT IN HDMI OUT IR IN IR OUT S PDIF IN S PDIF OUT DC 12V TX RX ETHERNET AUDIO OUT USB HOST USB DEVICE Ethernet Switch Etherne...

Страница 17: ...ay 3 Enter the default password admin and click Login Web UI Introduction The Web UI main page includes several tabs for basic and advanced settings including Video Control Audio Control Configuration...

Страница 18: ...n white to green to select the audio input for the output By default De EMBED IN1 routes to AUDIO OUT1 and HDMI OUT DE EMBED IN2 routes to AUDIO OUT2 and HDBT OUT De embedded Audio of HDMI OUT De embe...

Страница 19: ...io input Mute Click to mute unmute audio output By default the volume of MIC LINE audio input is 0dB CONFIGURATION 1 Input HDCP This section allows you to enable or disable HDCP capability of each inp...

Страница 20: ...tting of each input port CHAPTER 3 INSTALLATION AND OPERATION Apply Click to enable the EDID setting To set up the EDID setting for HDMI IN1 Go to the HDMI IN1 and select the settings from its drop do...

Страница 21: ...utomatically when there s no signal at the display for 3 minutes By default CEC Auto Control is set to ON 4 Output Resolution Configure EDID setting of each input port Set the scaler for HDMI OUT and...

Страница 22: ...default KEY LOCK is set as OFF 2 Network Network is used to set between the dynamic and static IP address DHCP When enabled the IP address of the Matrix is assigned automatically by the DHCP server co...

Страница 23: ...pgrade This section allows you to upgrade the Web UI To update the Web UI 1 Click Browse for the update bin file 2 Then click Upgrade to proceed 5 System This section allows you to reboot or reset the...

Страница 24: ...ctory defaults Click Factory Reset and then click OK in the pop up window Then wait 30 seconds to refresh and re login the Web UI CHAPTER 3 INSTALLATION AND OPERATION 6 Firmware Version This section a...

Страница 25: ...maximum per port adjustable 200mA maximum high IR output port IR Frequency Transmission Range 15kHz 460kHz Trigger Outputs Three 12 VDC 100mA max each Relays Three 30VDC 5 Amps Sense Inputs Three 3 24...

Страница 26: ...eT PoH RJ45 Resolution Range 800 x 600 60Hz to 4K x 2K 60Hz HDBaseT Transmission Distance 1080p 60Hz 100m 4K x 2K 60Hz 90m Switching Seamless EDID Management Built in EDID data and manual EDID managem...

Страница 27: ...s or have a question about your RTI product please contact RTI Technical Support for assistance see the Contacting RTI section of this guide for contact details RTI provides technical support by telep...

Страница 28: ...on System VXP 82 28 Remote Technologies Incorporated 5775 12th Avenue East Suite 180 Shakopee MN 55379 Tel 952 253 3100 Fax 952 253 3131 www rticorp com 2019 Remote Technologies Inc All rights reserve...

Отзывы: