4.1 The setting of current

Peak Current

Average Current

SW1

SW2

SW3

Remarks

1.4A

1.0A

on

on

on

Other

current can

be

customized

.

2.1A

1.5A

off

on

on

2.7A

1.9A

on

off

on

3.2A

2.3A

off

off

on

3.8A

2.7A

on

on

off

4.3A

3.1A

off

on

off

4.9A

3.5A

on

off

off

5.6A

4.0A

off

off

off

DIP SW1, SW2, SW3 are used to set current which is output from driver to motor.
Generally, the current setting is the motor rated current. If your system has high request to the heating,
please decrease the current properly to lower the motor’s heating, but at the same time, the output
torque will be lower. If you don’t need the motor running continuous, you can increase the current to
higher the torque. But be minded that the current can not be 1.5times over than the rated current.

4.2 The setting of pulse per revolution

Steps/revolution

SW5 SW6 SW7

SW8

Remarks

200

on

on

on

on

Other subdivisions can be customized

400

off

on

on

on

800

on

off

on

on

1600

off

off

on

on

3200

on

on

off

on

6400

off

on

off

on

12800

on

off

off

on

25600

off

off

off

on

1000

on

on

on

off

2000

off

on

on

off

4000

on

off

on

off

5000

off

off

on

off

8000

on

on

off

off

10000

off

on

off

off

20000

on

off

off

Off

25000

off

off

off

off

DIP SW5, SW6, SW7, and SW8 are used to set the pulse per revolution required by the motor.
Motor speed = command pulse frequency / pulse per revolution
Motor stroke = number of command pulses / pulse per revolution

Содержание Ruitech 3R60

Страница 1: ...3R60 User Manual szruitech com 3 Phase Stepper Motor Driver 3R60 User Manual Shenzhen Rtelligent Mechanical Electrical Technology Co ltd...

Страница 2: ...Port function description 3 3 2Power supply input 3 3 3Motor connection 4 3 4Control signal connection 5 3 4 1 PUL DIR port connection for pulse command 5 3 4 2 ENA port used to enable or disable 5 3...

Страница 3: ...and 8 current selections It has overvoltage undervoltage and overcurrent protection Its input and output control signals are optically isolated Power supply 24 50VDC Output current DIP switch setting...

Страница 4: ...nt 3R60 Installation environment Avoid dust oil and corrosive environment Vibration 0 5G 4 9m s2 Max Operating temperature humidity 0 45 90 RH or less no condensation Storage and transportation temper...

Страница 5: ...ans to ensure good heat dissipation conditions in the control cabinet 3 Driver port and connection 3 1 Port function description Function Grade Definition Remarks Power supply input port V Input DC po...

Страница 6: ...current at both ends of the motor winding In actual use the appropriate power supply should be selected according to the motor model load torque and other factors The effects of regeneration voltage W...

Страница 7: ...or disable When the internal optocoupler is off the driver outputs current to the motor When the internal optocoupler is on the driver will cut off the current of each phase of the motor to make the m...

Страница 8: ...Pul Dir Dir Ena Ena Vcc Vcc Difference Pul Pul Dir Dir Ena Ena Pul Pul Dir Dir Ena Ena 4 The setting of DIP switches and operating parameters The setting of current The setting of pulse per revolution...

Страница 9: ...If you don t need the motor running continuous you can increase the current to higher the torque But be minded that the current can not be 1 5times over than the rated current 4 2 The setting of puls...

Страница 10: ...is flickering Driver working normally One green indicator and one red indicator Driver overcurrent One green indicator and two red indicators Driver input power overvoltage One green indicator and thr...

Страница 11: ...of Pulse per revolution is wrong Check the DIP switch status and correctly connect the switches Encoder signal is abnormal Replace the motor and contact the manufacturer The driver terminal burned up...

Страница 12: ...reversed and insert pull the motor connection when the power supply is connected Beyond electrical and environmental requirements Change the internal device without permission 7 3 Maintenance process...

Отзывы: