3R60

User Manual

szruitech.com

9

The motor cable is disconnected

Check the connection

The motor has only one direction

Pulse mode error or DIR port damaged

Alarm indicator is

on

The motor connection is wrong

Check the motor connection

The motor connection and
encoder connection are wrong

Check the sequence of encoder connection

The voltage is too high or too low

Check the power supply

The position or

speed is wrong

The signal is disturbed

Eliminate interference for reliable
grounding

The command input is incorrect

Check the upper computer instructions to
ensure the output is correct

The setting of Pulse per revolution
is wrong

Check the DIP switch status and correctly
connect the switches

Encoder signal is abnormal

Replace the motor and contact the
manufacturer

The driver terminal

burned up

Short circuit between terminals

Check power polarity or external short
circuit

Internal resistance between
terminals is too large

Check whether there is any solder ball due
to excessive addition of solder on the wire
connections

The motor is out of

tolerance

Acceleration and deceleration
time is too short

Reduce command acceleration or increase
drive filtering parameters

Motor torque is too low

Select the motor with high torque

The load is too heavy

Check the load weight and quality and
adjust the mechanical structure

The current of power supply is too
low

Replace the appropriate power supply

Содержание Ruitech 3R60

Страница 1: ...3R60 User Manual szruitech com 3 Phase Stepper Motor Driver 3R60 User Manual Shenzhen Rtelligent Mechanical Electrical Technology Co ltd...

Страница 2: ...Port function description 3 3 2Power supply input 3 3 3Motor connection 4 3 4Control signal connection 5 3 4 1 PUL DIR port connection for pulse command 5 3 4 2 ENA port used to enable or disable 5 3...

Страница 3: ...and 8 current selections It has overvoltage undervoltage and overcurrent protection Its input and output control signals are optically isolated Power supply 24 50VDC Output current DIP switch setting...

Страница 4: ...nt 3R60 Installation environment Avoid dust oil and corrosive environment Vibration 0 5G 4 9m s2 Max Operating temperature humidity 0 45 90 RH or less no condensation Storage and transportation temper...

Страница 5: ...ans to ensure good heat dissipation conditions in the control cabinet 3 Driver port and connection 3 1 Port function description Function Grade Definition Remarks Power supply input port V Input DC po...

Страница 6: ...current at both ends of the motor winding In actual use the appropriate power supply should be selected according to the motor model load torque and other factors The effects of regeneration voltage W...

Страница 7: ...or disable When the internal optocoupler is off the driver outputs current to the motor When the internal optocoupler is on the driver will cut off the current of each phase of the motor to make the m...

Страница 8: ...Pul Dir Dir Ena Ena Vcc Vcc Difference Pul Pul Dir Dir Ena Ena Pul Pul Dir Dir Ena Ena 4 The setting of DIP switches and operating parameters The setting of current The setting of pulse per revolution...

Страница 9: ...If you don t need the motor running continuous you can increase the current to higher the torque But be minded that the current can not be 1 5times over than the rated current 4 2 The setting of puls...

Страница 10: ...is flickering Driver working normally One green indicator and one red indicator Driver overcurrent One green indicator and two red indicators Driver input power overvoltage One green indicator and thr...

Страница 11: ...of Pulse per revolution is wrong Check the DIP switch status and correctly connect the switches Encoder signal is abnormal Replace the motor and contact the manufacturer The driver terminal burned up...

Страница 12: ...reversed and insert pull the motor connection when the power supply is connected Beyond electrical and environmental requirements Change the internal device without permission 7 3 Maintenance process...

Отзывы: