MEMS Digital in-Place Inclinometer System  

Quick Start Up Guide 

 
 

 

ICM0095B 

RST Instruments Ltd. 

 

T

ABLE 

2-1

  

D

IGITAL OUTPUT FOR 

MEMS

 

IPI

 

4

 SYSTEM AND 

RST

 

DT2485 

Wire Color 

MEMS IPI 4 

Red 

V+ 

Green 

White 

Black 

GND 

Bare 

SH 

 

3.  Follow the instructions outline in Section 4 to configure the string. Ensure that 

serial numbers are entered in the same order as they appear on the string. 

4.  Disconnect all sensors and place the shipping caps on all connectors to prevent 

contamination. 

2.2 

I

NSTALLATION IN THE 

F

IELD

 

Once the system and communication have been configured in the office or 
warehouse, installation in the field will be straightforward. See ICM0062 for detailed 
instructions. 

 

 

 

2.2.1 

Cleaning Connectors 

Keep caps on connectors (Figure 2-3) until mated to the next sensor to prevent 
contamination. Store the caps in a clean, dry location for future use. 

Any dirt within the connectors may cause water ingress and cause an entire 
string of IPIs to fail.  

 

CAUTION:

 

C

ONTAMINATION

,

 SUCH AS DIRT OR DUST

,

 IN THE CONNECTORS CAN CAUSE 

READ FAILURES IN AN ENTIRE STRING OF 

IPI

S

In the event of contamination within the connectors, the connector ends may be 
flushed with isopropyl alcohol and set aside to dry.  

CAUTION:

 

I

T IS CRITICAL THAT THE SENSORS ARE INSTALLED IN THE SAME ORDER ON 

THE STRING AS IN THE INITIAL SET UP AND CONFIGURATION

.

 

R

EAD ERRORS 

AND SYSTEM FAILURE MAY OCCUR

Содержание MEMS IPI 4

Страница 1: ...his document RST Instruments Ltd reserves the right to change the information at any time and assumes no liability for its accuracy Copyright 2020 RST Instruments Ltd All rights reserved Document Numb...

Страница 2: ...ICM0095B RST Instruments Ltd Page i REVISION HISTORY Rev Revision History Date Prepared By Approved By A Initial release 2020 Nov 13 MP BN B Added instructions for Campbell CR6 and CR310 loggers DT L...

Страница 3: ...R QUICK START UP INSTRUCTIONS 9 5 1 Hardware Requirements 9 5 2 CR6 Wiring 10 5 2 1 Updating the Modbus Addresses With a CR6 10 5 2 2 Code for CR6 12 5 3 CR310 Wiring 14 5 3 1 Updating the Modbus Addr...

Страница 4: ...ger using C1 and C2 14 Figure 5 10 Select CRBasic editor under the Program menu 15 Figure 5 11 CR300 Series Program icon 15 Figure 5 12 Compiling and saving the code in the CRBasic editor 16 Figure 5...

Страница 5: ...To ensure that all components are working together correctly and able to communicate RST recommends that initial set up and configuration take place in the office or warehouse prior to final installa...

Страница 6: ...of each sensor and its order in the string from the top to the bottom of the string Connect the IPI string to the desired data logger following the wiring scheme outlined in Table 2 1 CAUTION IT IS C...

Страница 7: ...ehouse installation in the field will be straightforward See ICM0062 for detailed instructions 2 2 1 Cleaning Connectors Keep caps on connectors Figure 2 3 until mated to the next sensor to prevent co...

Страница 8: ...RE DT2485 logger or Campbell Logger o PC with LoggerNet and o RST ELGL4000 Interface if using CR310 3 2 PC HARDWARE Desktop or laptop with Intel or AMD processor USB port 3 3 WINDOWS HOST OPERATING SY...

Страница 9: ...sion The current version can be downloaded from https rstinstruments com resources software Navigate to the site and select the appropriate data logger 2 Follow the on screen instructions to install t...

Страница 10: ...Once the software connects to the logger the port and status indicators will turn green and the Status screen should display logger information 3 Navigate to the DTBus tab to configure the IPI sensors...

Страница 11: ...o the string Insert a sensor to the current position in the string Change communication between ASCII and Modbus Remove the currently displayed sensor from the string or remove all sensors Add specifi...

Страница 12: ...the Upload to Logger button to apply the changes Click Yes when asked to update Modbus Addresses 6 Wait for update process to finish The logger is now logging data 7 If desired real time sensor readi...

Страница 13: ...ile csv will automatically be created in the data directory The default data directory is My Documents Multichannel 3 Before downloading the program will ask whether you would like to erase the existi...

Страница 14: ...ses on the IPI string ensure that all settings have been saved on the logger unit Modbus addresses for sensors connected to a Campbell CR6 logger can be updated via a CRBasic code Once the user has de...

Страница 15: ...will depend on the type of logger that will be used 6 Update the number of IPIs and the serial number of each IPI in the code in order of installation or planned installation 7 Compile the code and th...

Страница 16: ...l LoggerNet instructions for ensuring current settings have been saved 12 Select Send New on the right hand side of the screen and open the saved CRBasic code from Step 7 13 Click on Start Running 14...

Страница 17: ...nsors per string EndTable Main Program BeginProg Open serial port SerialOpen ComC1 9600 0 0 128 4 SerialFlush ComC1 Guard against serial number error causing incorrect data SerialOut ComC1 65534 MBA 2...

Страница 18: ...gure 5 9 FIGURE 5 9 WIRING SCHEMATIC FOR AN IPI SYSTEM TO THE CR310 LOGGER USING C1 AND C2 5 3 1 Updating the Modbus Addresses With a CR310 Before updating the Modbus addresses on the IPI string ensur...

Страница 19: ...Ensure that any existing settings have been saved 5 Remove the template code and paste the code see Section 5 3 2 into the editor The appropriate code will depend on the type of logger that will be u...

Страница 20: ...COMPILING AND SAVING THE CODE IN THE CRBASIC EDITOR 8 If the compilation was successful the following message will appear at the bottom of the window FIGURE 5 13 SUCCESSFUL COMPILATION MESSAGE 9 Close...

Страница 21: ...ct Send New on the right hand side of the screen and open the saved CRBasic code from Step 7 13 Click on Start Running 14 The Modbus addresses for the sensors on the IPI string will now be updated 5 3...

Страница 22: ...in interface banner set mode on program run continuous reading mode SerialOut Com1 MODE 0 CHR 13 1 0 SerialIn interface_banner Com1 200 CHR 13 100 Delay 0 1 Sec SerialFlush Com1 Guard against serial n...

Страница 23: ...nts Ltd 19 6 INSTALLATION Refer to the MEMS Digital In Place Inclinometer System Instruction Manual ICM0062 for detailed installation instructions 7 SERVICE AND REPAIR This product contains no user se...

Отзывы: