MEMS Digital In-Place Inclinometer System
Quick Start Up Guide
ICM0095B
RST Instruments Ltd.
9
8. Under the
Status
tab, check to make sure the parameters are correct and
that the logger is either
logging
or there is a
log pending
under the
Sampling
section.
9. Click
Disconnect
button to terminate logger connection.
10. Exit the software and disconnect the communication cable.
11. The data logger should now be taking readings. Return to the logger to
download the data. Check the remaining battery life every time you connect.
The battery state is an approximate value based on recent battery use.
4.4
D
OWNLOADING
D
ATA
1. Connect the communication cable to your computer and the DT2485 and
launch the software. If the connection is successful, the port and status
indicators turn green and the
Status
screen should display logger
information.
2. Press the
Collect Data
button on the
Status
tab to download the data. A data
file (*.csv) will automatically be created in the data directory. The default data
directory is:
My Documents\Multichannel\
3. Before downloading, the program will ask whether you would like to erase
the existing data on the logger or keep appending to existing records. To
erase the old data and continue logging with the same parameters, select
the
Logging
tab and press
Apply Settings.
4. To keep the old data on the logger and continue logging, exit the program,
and disconnect the communication cable.
5. To change any logging parameters, do so under the
Logging
tab and press
Apply Settings
to save the changes.
6. Disconnect the communication cable when finished.
4.5
H
ELP
S
YSTEM
An extensive help system in DT Logger Host can be activated anytime by pressing
F1 or the RST icon. Answers to common problems and troubleshooting tips can be
found by browsing help topics or searching using keywords.
5
C
AMPBELL
L
OGGER
Q
UICK
S
TART
U
P
I
NSTRUCTIONS
The following is a brief outline to update the Modbus addresses of IPI sensors in a
string with a CR6 or CR310 Campbell logger. Before
5.1
H
ARDWARE
R
EQUIREMENTS
•
Campbell Logger
o
CR6