MEMS Digital In-Place Inclinometer System
Quick Start Up Guide
ICM0095B
RST Instruments Ltd.
10
o
CR310
▪
RST ELGL4000 Interface
•
PC with the latest version of LoggerNet
5.2
CR6
W
IRING
To connect the IPI system to a CR6 Campbell logger, follow the wiring schematic
outlined in Figure 5-1.
F
IGURE
5-1
CR6
WIRING SCHEMATIC
5.2.1
Updating the Modbus Addresses With a CR6
Before updating the Modbus addresses on the IPI string, ensure that all settings
have been saved on the logger unit.
Modbus addresses for sensors connected to a Campbell CR6 logger can be
updated via a CRBasic code. Once the user has defined the number of sensors
and their respective serial numbers, the code will automatically assign a Modbus
address to each sensor in the string once the code is run.
1. Open LoggerNet.
2.
Navigate to the “CRBasic Editor” option under the
Program
menu (Figure 5-2).
F
IGURE
5-2
S
ELECT
CRB
ASIC
E
DITOR UNDER THE
P
ROGRAM MENU
3. Select the appropriate logger from the menu, depending on the type of logger
used.