10. If the blower fails to operate, check the following:
a
) Consult the wiring diagram to assure proper con-
nections.
b
) To assure proper contact, check the motor lead
wiring, incoming supply wiring and capacitor connec-
tions.
c
) If possible, use a meter to test for continuity between
the fan leads. Please note that the capacitor will show
no reading if it is tested with a meter.
11. If the blower still fails to operate, consult your local
RSF Woodburning Fireplaces authorized dealer for
repair/replacement instructions.
Page 31
Black
White
Ground (bare)
Speed
control
Thermo-
stat
Option1:
warn-
ing thermostat
(see schematic
wiring diagram
Figure 36)
Blower
control
detail
To
thermostat
To speed
control
To terminal
Option 2:
cooling thermostat
(see schematic
wiring diagram
Figure 36)
BWG
Blower
detail
Blower
Blower
control
Terminal
bloc
Terminal detail
Figure 30: Central heat system wiring diagram
110 V
Red
Yellow
To blower
OPEL AP