Page 20
OPEL AP
Terminal switch
Mounting clips
Thermal switch
Circulating blower
Bottom louver
Louver retention
Figure 17: Circulating blower location (sectional view)
2. Remove the ash pan, to do so, you will need to remove
the plug from the inside of the firebox.
3. Remove the ash pan’s drawer. Remove the screw locat-
ed on the right hand side of the drawer at its back.
4. Mount the blower on its 90º bracket. Be sure that the
wires are connected to the blower before mounting
5. Hold the blower with the outlet facing up from the back.
Fit the blower through the louver opening.
6. Slide the blower into place between the two brackets.
You should see the wheels of the blower.
7. Mount the thermal switch on its support as shown in
(Figure 17). The thermal switch support is located just
beneath the bottom of the firebox on the right hand side
leg. Push the clips on to the support as far as they will
go.
NOTE: One thermal switch is all that is required to oper-
ate the internal blower, the central heat blower, or both.
8. Locate the provided speed control in a switch box at a
convenient location on the wall and connect it with con-
ventional 90° C 14 gauge wire (see Figure 16).
9. Replace the ash pan drawer and srew, the ash pan and
the louver.