background image

30

PX4 AIR

®

LIMITED WARRANTY

RPB

®

 warrants that its Products will be free from defects in materials and workmanship for one (1) 

year, subject to the terms of this limited warranty.  The Products are sold only for commercial use, 
and no consumer warranties apply to the Products. This limited warranty is for the benefit of the 
original Product purchaser, and cannot be transferred or assigned. This is the sole and exclusive 
warranty provided by RPB

®

, and ALL CONDITIONS AND IMPLIED WARRANTIES (INCLUDING 

ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE) 
ARE EXCLUDED AND DISCLAIMED FROM WARRANTY COVERAGE.  RPB’s

®

 limited warranty 

coverage does not apply to damage resulting from accident, improper use or misuse of the 
Products, wear and tear resulting from the normal use of the Products, or the failure to properly 
maintain the Products.

RPB’s

®

 limited warranty coverage runs from the original date of purchase of the Products, and 

applies only to warranted defects which first manifest themselves and are reported to RPB

®

 within 

the warranty period.  RPB

®

 retains the right to determine to its reasonable satisfaction whether 

any claimed defect is covered by this limited warranty.

If a warranted defect occurs, RPB

®

 will repair or replace the defective Product (or a component 

of the Product), in its sole discretion.  This “repair or replacement” remedy is the sole and 
exclusive remedy under this limited warranty, and under no circumstances shall RPB’s

®

 liability 

under this limited warranty exceed the original purchase price for the Products (or the applicable 
component). RPB

®

 has no responsibility for incidental or consequential damages, including loss 

of use, maintenance and other costs, and ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES 
ARE EXCLUDED AND DISCLAIMED from this limited warranty.  Contact RPB

®

 to obtain warranty 

service. Proof of purchase must be provided to obtain warranty service.  All costs of returning the 
Products to RPB

®

 for warranty service must be paid by the purchaser.

RPB

®

 reserves the right to improve its Products through changes in design or materials without 

being obligated to purchasers of previously manufactured Products.

LIABILITY

RPB

®

 Safety cannot accept any liability of whatsoever nature arising directly or indirectly from 

the use or misuse of RPB

®

 Safety products, including purposes that the products are not designed 

for. RPB

®

 Safety is not liable for damage, loss or expense resulting from the failure to give advice 

or information or the giving of incorrect advice or information, whether or not due to RPB

®

 

Safety’s negligence or that of its employees, agents or subcontractors.

Содержание PX4 Air

Страница 1: ...on Manual and carry out the Employer Responsibilities page 7 Product users Read this manual and the head top Instruction Manual and follow the Product User Safety Instructions page 9 Manuals are regul...

Страница 2: ...llowing signal word and safety symbols are used in this manual and product labeling WARNING indicates a hazardous situation that if not avoided could result in death or serious injury Read the Instruc...

Страница 3: ...ty means any patent patented articles patent applications designs industrial designs copyrights software source code database rights moral rights inventions techniques technical data trade secrets kno...

Страница 4: ...nt for loose fitting respirators such as helmets and face shields PROTECTION PROVIDED AND LIMITATIONS Improper selection fit use or maintenance of this product can result in injury life threatening de...

Страница 5: ...rtridge was installed into the PX4 AIR PAPR MARKINGS AND SYMBOLS ON THE EQUIPMENT Read all instructions before use Li Ion Lithium Polymer Batteries Batteries shall be disposed of as electronic waste R...

Страница 6: ...schedules or observe ESLI to ensure that cartridge and canisters are replaced before breakthrough occurs I Contains electrical parts that may cause an ignition in flammable or explosive atmospheres J...

Страница 7: ...riate for the intended activities and environments of use For example select a respirator appropriate to the specific airborne hazards with consideration of workplace and user factors and with an Assi...

Страница 8: ...reads both these manuals Ensure that equipment is properly set up used and maintained Make sure that equipment is properly set up inspected fitted used and maintained including selection of the appro...

Страница 9: ...4 AIR PAPR See Respirator Component Diagram page 6 See the instruction manual and approval label for the selected head top for approval with the PX4 AIR and the assigned protection factor Use only aut...

Страница 10: ...lter cartridge for the contamination and application PAPR Once the contamination level has been confirmed determine the correct filter cartridge to be used for the application to make sure that you ar...

Страница 11: ...NTS Welding and Grinding For welding grinding and other applications that produce sparks or high heat be sure to use the FR Fire Retardant specific model of the PX4 AIR with the FR belt and spark arre...

Страница 12: ...t attempt to service the chargers There are no user serviceable parts inside Use only the provided charger and cord Where to charge Charge only indoors in a dry area away from sources of heat away fro...

Страница 13: ...4 F to 113 F Do not disassemble Do not immerse in water or other liquids The battery can short if the contacts are accidentally connected by metal other than the PX4 AIR or the charger The protections...

Страница 14: ...position making sure that the latch snaps into place FIGURE 2 5 FIGURE 2 6 To remove the battery from the charging station press the release latch on the bottom of the battery and lift the battery fro...

Страница 15: ...iciency OV HE Filter Use the OV HE combination filter 03 995 in atmospheres that may contain organic vapors and gases such as solvents Some of these gases and vapors include sulphur dioxide chlorine h...

Страница 16: ...t rotate the door to the left and latch in place In environments with sparks such as welding or grinding use the 03 982 Spark Arrestor in front of the 03 981 Prefilter This will reduce the risk of fir...

Страница 17: ...and lift the door off the latch 1 2 Remove the 03 985 filter from the Door and dispose of it in a suitable way Install the new replacement 03 985 filter as per Fig 3 3 and 3 4 Inspect the 03 981 Prefi...

Страница 18: ...arrestor in situations there may be sparks such as welding and grinding Attach the front cover by pressing it onto the front of the cartridge until it clicks into place after the cartridge has been i...

Страница 19: ...at suits your respirator head top check that the fitting connects to your respirator type Take the end that fits to the respirator and connect it securely FIGURE 5 1 FIGURE 5 2 FIGURE 5 3 FIGURE 5 4 W...

Страница 20: ...r 04 091 is in the safe range before use so that there is sufficient air flow POWER BUTTON AND BATTERY INDICATION The top row of green lights indicate the charge of the battery 3 lights is fully charg...

Страница 21: ...1 cannot be achieved Speed 240 slpm The blue lights indicate the selected fan speed The red lights indicate the level of blockage When the lights flash red and blue the selected fan speed cannot be re...

Страница 22: ...replace the filter with a new one LOW BATTERY CHARGE ALARM A pulsing alarm sounds when approximately 10 15 minutes of charge is left in the battery Leave the work area Power the unit off and remove t...

Страница 23: ...Welding grinding where sparks may be present and High Heat Applications BELT AND SUPPORT ATTACHMENT Take the loose end of the Belt and thread from behind through the outer slot slot furthest out from...

Страница 24: ...nner slot from the back and then back through the outer slot Now thread the clip end of the buckle on to the belt and pull to the desired length BELT AND SUPPORT ATTACHMENT CONTINUED FIGURE 7 5 FIGURE...

Страница 25: ...er must not be cleaned or submersed in water at any time Damage to the HE filter paper will affect its ability to filter the air and could expose users to harmful environments All damaged filters pre...

Страница 26: ...elt Loops and screw in tight until secure Do not over tighten FIGURE 8 1 WARNING STORAGE The PX4 AIR should not be transported or stored with the filter or battery attached if not being used for long...

Страница 27: ...optimal temperature range for storage to maximise the life of the battery BATTERY RUN TIMES Lithium ion HE Filter Speed 1 Greater than 9 hours Speed 2 Greater than 7 hours Speed 3 Greater than 6 hours...

Страница 28: ...28 PX4 AIR PARTS AND ACCESSORIES FIGURE 9 1 1 3 2 4 5 7 8 9 10 11 12 10 13 6 14 15 16 17 19 21 20 18 22...

Страница 29: ...Cord 03 952 24 Volt Power Supply with Power Cord AU 03 952 AU 24 Volt Power Supply with Power Cord EU 03 952 EU 24 Volt Power Supply with Power Cord UK 03 952 UK 17 Battery Charger and Power Supply K...

Страница 30: ...ect occurs RPB will repair or replace the defective Product or a component of the Product in its sole discretion This repair or replacement remedy is the sole and exclusive remedy under this limited w...

Страница 31: ...31 NOTES...

Страница 32: ...ance your safety Designed to increase your productivity RPB T LINK Built off the Z Link platform the T Link is designed to work with you not against you Gone are the days of having to fight against a...

Отзывы: