Ri 6230-01
October 10, 2000
Page 19
3. The following screen will be displayed.
4. Select the mode according to the end users specification. Default setting: Energystar
TM
compliance.
Display
Contents
Instant Ready
Energystar
TM
compliance
E2000
Top Runner compliance
(
New Addition for Japan Specification
)
The fixing control temperature will not be lowered and only
the operation panel display will be turned OFF.
The fixing control temperature in the preheat/energy saver
mode will be lowered by 20
°
C. When the recovery mode
begins, the machine will become ready to copy in thirty (30)
seconds.
The fixing control temperature will be lowered by 25
°
C in the
preheat/energy saver mode.
Control in compliance with "Top Runner". (See below.)
5. Press the start key to set the selection.
6. Press the stop/clear key to exit the mode.
Specifications when the "Top Runner" compliance setting is selected
The fixing control temperature in standby mode will be lowered by 10
°
C.
Control during the preheat/energy saver mode
Control temperature: 140
°
C
The ON/OFF condition of the Heater will be controlled by the power relay ON/OFF control. When the
heater is OFF, the power relay will be OFF. When the machine begins the recovery period from the
preheat/energy saver mode, if the outside temperature of the machine is between 18
°
C and 25
°
C, the
machine will become ready to copy in thirty (30) seconds.