Ri 6230-01
October 10, 2000
Page 12
Email Function Limitations
Note: If SIM 338 is set to “Little” (default) and a 5 sheet E-mail is attempted, an error message will
display. If the E-mail function is to be utilized effectively, set SIM 338 to “Unlimited”.
Upgrading the Firmware on the Printer Board
Please follow below procedure for upgrading the firmware version of the printer board.
1.
Connect the PC (Win95/ 98/ NT4.0) to the printer locally with an IEEE 1284 parallel cable.
2.
Turn the MSW “ON” and confirm that the printer is online.
3.
Copy the firmware file to a directory (folder) on the PC hard drive.
4.
Start “DOS Prompt”, and change the current directory to the directory which you copied the
firmware to.
5.
Input echo !R!UPGR”SYS” ;
exit;>lpt1
and press enter key.
6.
Input copy /b (file name) lpt1 and press enter key. The firmware data will be transferred to the
printer via the parallel cable.
7.
Go to the printer, push [Copy/ Printer] button to change to printer mode.
8.
Confirm that the display shows “Please Wait”.
9.
Please wait. (approx. 5min)
10. During this waiting period, please do not copy to the printer. The Online/ Offline key is disabled.
11. After 5min, confirm that the display shows “Ready to Print”.
12. Turn the MSW off/ on. The upgrading is completed.
13. Output “Status Page” and confirm the new firmware version.
E-mail Size Limit Setting
1. Scanner Delivery Utility (Mail Block)
2. SIM 338 (E-mail size limit setting)
Little (default) :4 sheets max
Medium
:10 sheets max
Large
:20 sheets max
Unlimited
:Unlimited capacity
Text/OCR mode(300dpi)
2sheet
Mix mode(300dpi)
Photo mode
Not supported
The E-mail function cannot be used if either 1 of the below 2 restrictions applies.
Sending E-mail