19
FUEL SYSTEM
12
REPAIR
HEATER PLUG CONTROL UNIT
Service repair no - 19.60.33
Remove
1. Disconnect battery.
2. Remove screw securing control unit to bulkhead.
3. Disconnect multi-plug and release control unit.
Refit
4. Fit harness multi-plug to control unit.
5. Secure control unit to bulkhead.
6. Reconnect battery.
AIR CLEANER
Service repair no - 19.10.01
Remove
1. Slacken hose clip and detach outlet hose.
2. Release clips and open air cleaner retaining
straps.
3. Lift up air cleaner, slacken hose clip and detach
inlet hose.
4. Remove air cleaner.
Refit
5. Position air cleaner and connect inlet hose.
6. Close air cleaner retaining straps and secure
lock clips.
7. Connect outlet hose.
NOTE: If an EGR fuel system is fitted,
ensure the modulator valve vacuum spill
pipe is secure in the outlet hose.
AIR CLEANER ELEMENT
Service repair no - 19.10.10
For remove and refit procedure.
See SECTION 10,
Maintenance, Under bonnet maintenance