80
HEATING AND VENTILATION
8
REPAIR
8. Release lever assembly and disconnect 3
blower motor leads, noting their positions.
9. Pull control cable through bulkhead grommet
and out from instrument panel cowl.
10. Release retaining clip securing outer cable to
lever assembly.
11. Release inner cable from lever peg.
NOTE: If the blower motor switch is faulty
the complete lever assembly will have to
be renewed.
Refit
12. Fit new control cable to lever assembly peg.
13. Fit retaining clip to secure outer cable.
14. Reconnect blower motor leads.
15. Route cable to rear of instrument panel cowl,
along bulkhead and out through grommet into
engine compartment.
16. Fit lever assembly to panel cowl. Ensure screw
spacers are fitted between cowl and lever
assembly.
17. Fit instrument panel to fascia cowl.
18. With lever in closed position, fit control cable to
heater unit flap lever trunnion.
19. Secure outer cable with retaining clip.
20. Secure control cables to engine bulkhead and
heater hoses with retaining clips.
21. Reconnect battery.
Содержание DEFENDER 300Tdi
Страница 310: ...76 CHASSIS AND BODY 2 DESCRIPTION AND OPERATION LAND ROVER 90...
Страница 312: ...76 CHASSIS AND BODY 4 DESCRIPTION AND OPERATION LAND ROVER 110...
Страница 314: ...76 CHASSIS AND BODY 6 DESCRIPTION AND OPERATION LAND ROVER 130...
Страница 317: ...CHASSIS AND BODY 1 REPAIR DOORS RH rear door lock mechanism RH front door lock mechanism...
Страница 415: ...86 ELECTRICAL 8 DESCRIPTION AND OPERATION...
Страница 417: ...86 ELECTRICAL 10 DESCRIPTION AND OPERATION...