X935-24-00 Rev 108 V894CSH/V894WSH High-Security Cameras
Technical Information
•
11
Technical Information
ELECTRICAL
Input
Voltage:
24 VAC ±20%, isolated input.
Current
Rating:
200 mA.
Power Consumption:
4.8
W.
Heat Equivalent:
0.27 btu/min (0.07 kg-cal/min).
Note: These figures represent the conversion of 100% of the electrical energy to heat. Actual percentage of
heat generated will be less and will vary from product to product. These figures are provided as an aid
in determining the extent of cooling required for an installation.
Maximum Operating Distance:
Wire Size (AWG)
(Annealed Copper Wire)
Maximum Distance
ft (m)
20
1200 (366)
18
1875 (572)
16
3000 (914)
14
4800 (1463)
12
6000 (1829)
Connectors:
Power: 3-pin screw terminal block.
Video: BNC.
Fuse:
Resettable.
Radio Frequency Emission Rating:
FCC Class A.
OPERATIONAL
Tilt and Horizontal Adjustment:
3 axis adjustment, tilt, vertical height of camera/lens and roll
(lens may be rotated on its axis 360º).
OPTICAL
Light Loss through Window:
Negligible.
Camera/Lens Specifications:
Refer to Table 4.