Environmental Specifications
Max Altitude:
2,000m (6,560 ft)
Ambient Temperature:
For standard and Ex e d/Ex h and Ex tb product variants:
-25° to +65°C (-13°F to 149°F) with 1A max current
-25°C to +40°C (-13°F to 104°F) with 5A max current
For Ex ib, Ex h product variants: -25°C to +100°C (-13°F to 212°F)
Determination of the ambient temperature for the installed product should
consider external heat sources, such as process temperatures or solar
heating, as appropriate.
Sealing:
IP67
Vibration:
The product is designed to be installed in a vibration-free environment. If
prolonged or severe vibrations are likely, please contact Rotork for advice.
3.3
Electrical Specifications
Max Voltage & Current:
For standard variants fitted with micro-switches: 120 Vac/15 Vdc, 5A
For standard variants fitted with proximity sensors: 8 Vdc
For Ex e d/Ex h and Ex tb product variants: 120 Vac/15 Vdc, 5A (T
amb
to
40°C), 1.5 A (T
amb
to 65°C)
For Ex i, Ex h product variants: U
i
16V, I
i
25 mA, P
i
64 mW (per separate IS
circuit)
3.4
Operational Specifications
Life:
2 million input shaft turns, each direction
Duty:
Manual operation, service as per parent gearbox
Max Operating Rim Effort:
356N (80 lbs)
Overload Capability:
1.5x rated torque
Direction:
Clockwise in
–
clockwise out
3.5
Functional Specifications
Type
Ratio
Min Turns
Max Turns
Weight / kg
SPI 1
34.8:1
4
26
6.4
SPI 2
113.3:1
13
87
6.4
SPI 3
368:1
42
284
6.6
SPI 4
1196:1
137
923
6.7
Base Mounting:
ISO5210 F10
Non-Thrust Valve Shaft Dimensions:
Ø20mm with single 6mmx6mm keyway
Non-Thrust Shaft Engagement:
60mm
Thrust Taking Valve Stem Dimensions: Machining within a Ø20mm circle
Thrust Taking Max Stem Engagement: 135mm
Max Thrust:
40kN (8992 lb ft.)
Thrust Taking Unit Additional Weight: 3.6kg
4
Storage
SPI units should be stored in a clean and dry environment. They should be protected against condensation
inside the packaging. Direct contact with wet timber pallets and packing cases should be avoided. Storage
temperature should be between 0°C and 40°C (32°F and 104°F).
SPI design life is 40 years from manufacture date, inclusive of storage duration.