Pipe Connections

Supply and return connections

  

The pipe connections on the attached ball valves are 1 1/2” FPT. Use of a thread  

        sealant compatible with water service is recommended.

Loop Connections

Loop connections are standard threaded R-30 Euroconical compression fitting  

        assemblies.

  

Care should be taken to ensure that the tubing ends are cut square, and that there is no debris    

in the end of the tubing that may affect the integrity of the fitting. 

Loop tubing approach to the manifold should be carefully managed to allow for minimum bend    

radius requirements and bend supports should be used if there are concerns for tubing kinking    

during manifold and floor installation and finishing.

Caution:

 Alu-Laser Plus tubing must be reamed with Roth Alu-Laser Plus reaming tool. This 

puts a bevel on the inside of the pipe and allows the fitting to be inserted into the pipe without 

disturbing the o-rings on the fitting. Failure to do so will cause leaks. 

Attaching Tubing to Manifold

• 

Place compression nut onto tubing with thread opening facing tubing end

• 

Fit split ring over tubing and move away from end at least 2” (50mm)

•  Insert fitting into tubing until all barbs are covered

•  Insert euroconical end of fitting into manifold until o-ring is seated

•  Push split ring up against fitting

• 

Thread and tighten nut onto manifold 

Roth Product #

Description

PEX/PE-RT Fittings

2335001410

  Manifold Tubing Fitting Assembly - 3/8”   pkg of 10

2350003021

  Manifold Tubing Fitting Assembly - 1/2”   pkg of 10

2350003022

  Manifold Tubing Fitting Assembly - 5/8”   pkg of 10

2335001034

  Manifold Tubing Fitting Assembly - 3/4”   pkg of 2

Alu-Laser Plus Fittings

2347131300

  Manifold Tubing Fitting Assembly - 3/8”   pkg of 10

2347002331

  Manifold Tubing Fitting Assembly - 1/2”   pkg of 10

2347002332

  Manifold Tubing Fitting Assembly - 5/8”   pkg of 10

Содержание CM Manifold

Страница 1: ...Roth Industries Inc 268 Bellew Avenue South Watertown NY 13601 Ph 315 755 1011 Fax 315 475 0200 www roth usa com info roth usa com Roth CM Manifold System Installation Instructions Roth Roth...

Страница 2: ...fold basic kit including Manifold cross pieces Temperature gauges Drain fill valves Mounting brackets Supply manifold segments 1 6 with adjustable flowmeters Return manifold segments 1 6 with manual v...

Страница 3: ...50 70 90 110 130 150 F 30 50 70 90 110 130 150 F Specifications Parameter Value Operating Temperature and Pressure Maximum 140 F 87 psi 60 C 6 bar Maximum 194 F 43 psi 90 C 3 bar Maximum Operating Pre...

Страница 4: ...until they hit the end stop 2 Tee segment has four connection points on top bottom and two sides Each connection has a plug which can be removed with a large slotted screwdriver Ball Valve 1 Ball val...

Страница 5: ...Manifold system locations should not be in flood prone areas or exposed to the elements 4 Avoid exposing tubing to direct sunlight even through a door or window Long term exposure to UV rays will cau...

Страница 6: ...fect on the flow rate but may cause flow indicators to give false readings or stop working altogether b The flow indicators will indicate flow however they will lose some of their precision in this or...

Страница 7: ...amed with Roth Alu Laser Plus reaming tool This puts a bevel on the inside of the pipe and allows the fitting to be inserted into the pipe without disturbing the o rings on the fitting Failure to do s...

Страница 8: ...s Attach service hoses to barbed fittings on supply and return manifold fill drain valves and secure with hose clamps Open fill drain valves Open all loop supply and return main valves Open water sour...

Страница 9: ...nts until water seeps out and close Shut off the water source close fill drain valves and remove service hoses Pressure Testing Air test Pressurize system to 87 psi 6 bar for a minimum of 2 hours Pres...

Страница 10: ...g 1 up and turn flowmeter 2 counterclockwise Once the flow rate is set turn stop ring clockwise until the stop engages the stop on the flowmeter Push the stop ring down to lock 1 2 1 2 3 4 5 6 7 8 9 1...

Отзывы: