5/9
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.6.3.2
[4-09]
R/W
0: Current
1: Power
A.6.3.3
[5-05]
R/W
0~50 A, step: 1 A
50 A
A.6.3.4
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.6.3.5.1
[5-05]
Amp. limits for DI
Limit DI1
R/W
0~50 A, step: 1 A
50 A
A.6.3.5.2
[5-06]
Amp. limits for DI
Limit DI2
R/W
0~50 A, step: 1 A
50 A
A.6.3.5.3
[5-07]
Amp. limits for DI
Limit DI3
R/W
0~50 A, step: 1 A
50 A
A.6.3.5.4
[5-08]
Amp. limits for DI
Limit DI4
R/W
0~50 A, step: 1 A
50 A
A.6.3.6.1
[5-09]
kW limits for DI
Limit DI1
R/W
0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.2
[5-0A]
kW limits for DI
Limit DI2
R/W
0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.3
[5-0B]
kW limits for DI
Limit DI3
R/W
0~20 kW, step: 0,5 kW
20 kW
A.6.3.6.4
[5-0C]
kW limits for DI
Limit DI4
R/W
0~20 kW, step: 0,5 kW
20 kW
A.6.3.7
[4-01]
R/W
0: None
1: BSH
2: BUH
└─
Averaging time
A.6.4
[1-0A]
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─
Ext amb. sensor offset
A.6.5
[2-0B]
R/W
-5~5°C, step: 0,5°C
0°C
└─
Boiler efficiency
A.6.A
[7-05]
R/W
0: Very high
1: High
2: Medium
3: Low
4: Very low
└─
Emergency
A.6.C
R/W
0: Manual
1: Automatic
└─
Overview settings
A.8
[0-00]
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
A.8
[0-01]
R/W
[9-05]~[9-06]°C, step: 1°C
45°C
A.8
[0-02]
R/W
10~25°C, step: 1°C
15°C
A.8
[0-03]
R/W
-40~5°C, step: 1°C
-10°C
A.8
[0-04]
R/W
[9-07]~[9-08]°C, step: 1°C
8°C
A.8
[0-05]
R/W
[9-07]~[9-08]°C, step: 1°C
12°C
A.8
[0-06]
R/W
25~43°C, step: 1°C
35°C
A.8
[0-07]
R/W
10~25°C, step: 1°C
20°C
A.8
[0-0B]
R/W
35~[6-0E]°C, step: 1°C
55°C
A.8
[0-0C]
R/W
45~[6-0E]°C, step: 1°C
6
0°C
A.8
[0-0D]
R/W
10~25°C, step: 1°C
15°C
A.8
[0-0E]
R/W
-40~5°C, step: 1°C
-10°C
A.8
[1-00]
R/W
-40~5°C, step: 1°C
-10°C
A.8
[1-01]
R/W
10~25°C, step: 1°C
15°C
A.8
[1-02]
R/W
[9-01]~[9-00], step: 1°C
35°C
A.8
[1-03]
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
25°C
A.8
[1-04]
R/W
0: Disabled
1: Enabled
A.8
[1-05]
R/W
0: Disabled
1: Enabled
A.8
[1-06]
R/W
10~25°C, step: 1°C
20°C
A.8
[1-07]
R/W
25~43°C, step: 1°C
35°C
A.8
[1-08]
R/W
[9-03]~[9-02]°C, step: 1°C
22°C
A.8
[1-09]
R/W
[9-03]~[9-02]°C, step: 1°C
18°C
A.8
[1-0A]
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
A.8
[2-00]
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
A.8
[2-01]
R/W
0: No
1: Yes
When should the disinfection function be executed?
Should the disinfection function be executed?
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
What is the averaging time for the outdoor temp?
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
Weather dependent cooling of the main leaving water temperature zone.
Weather dependent cooling of the additional leaving water temperature zone
Low ambient temp. for LWT main zone cooling WD curve.
Low ambient temp. for LWT add zone cooling WD curve.
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Low ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Low ambient temp. for LWT add zone heating WD curve.
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
High ambient temp. for LWT add zone cooling WD curve.
kW value
Priority
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Type
Amp. value
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*