12
x
Technical data
ROTEX GCU compact -
59
12.2 Gas type, connection pressures
1
Type
2
Unit type
3
Product-ID (CE-Number)
4
NOx-class
5
Rated thermal load
6
Nominal output
7
Country of destination
8
Voltage supply
9
Electr. power input
10
Degree of protection
11
Net weight
12
Max. permissible operating pressure (heater)
13
Max. permissible operating temperature
14
Max. operating pressure (sanitary)
15
D value
16
Serial number (indicate for complaints and inquir-
ies)
17
Burner configuration
18
Gas type
19
Minimum burner load
20
Max. burner load
21
Gas type
22
Minimum burner load
23
Max. burner load
Fig. 12-1 Information on the Type plate (top) and settings type plate (bottom) — Information
regarding the positions see tab. 12-1 to tab. 12-6
Gas type
Rated pressure in mbar
Min. inlet pressure in mbar
Max. inlet pressure in mbar
Natural gas E/H
20
17
25
Natural gas LL/L
20
18
25
Liquid petroleum gas
50
42.5
57.5
Tab. 12-5 Permitted gas inlet pressure
Country of destination
Appliance category
Nominal connection pressure in
mbar
Natural gas
Liquefied
petroleum gas
Natural gas
Liquefied
petroleum gas
DE
II
2N3P
20/25
50
DE
II
2ELL3P
20
50
AT, CH, CZ, SK
II
2H3P
20
50
CH, ES, FR, GB, IE, GR, IT, HR, PT, SI, LT, SK
II
2H3P
20
37
ES, FR, GR, PT, SI
II
2N3P
20/25
37
NL
II
2L3P
25
37
HU
II
2H3P
25
30
FR
II
2E+3P
20/25
37
FR
II
2Er3P
20
37
DK, FI, LV, NL, NO, SE, TR
I
2H
20
BE
I
2E+
I
3P
20/25
37
BE
I
2N
20/25
LU
I
2E
20
Tab. 12-6 Countries of destination, unit categories and associated gas connection pressures