56
ROTEX GCU compact -
12
x
Technical data
12 Technical data
12.1 Basic data
12.1.1 GCU compact 3xx
Type
(1)*
GCU compact 315 / 315 BIV GCU compact 324 / 324 BIV
Parameter
Unit
Total storage capacity
Litres
300
Empty weight
(11)*
kg
86
Total filled weight
kg
386
Dimensions (L x B x H)
cm
59.2 x 61,5 x 195
Maximum permissible storage water temperature
°C
85
Stand-by heating power
kWh/24h
1.7
Drinking water heat exchanger (stainless steel)
Water capacity heat exchanger
Litres
19.0
Heat exchanger surface area
m
2
4
Max. operating pressure for the potable water P
MW
(14)*
bar
6
Storage tank charging heat exchanger (stainless steel)
Water capacity heat exchanger
Litres
9.4
Heat exchanger surface area
m
2
1,9
Pressurised solar heat exchanger (stainless steel)
Water capacity heat exchanger
Litres
— / 4.2
— / 4.2
Heat exchanger surface area
m
2
— / 0.8
— / 0.8
Pipe connections
Cold and hot water
Inch
1" AG
Heating feed and return flow
Inch
1" IG
Thermal performance data (sanitary)
Efficiency characteristic N
L
according to DIN 4708
1)
2.0
2.1
D-value (specific Water flow) according to EN 625
2)
(15)*
l/min
22
24
Continuous rating Q
D
according to DIN 4708
kW
15
24
Max. draw-off rate for a period of 10 min at
(TKW = 10°C / TSP = 60°C / TWW = 40°C)
Litres
19
21
Hot water quantity without reheating up to 15 l/min
tapping rate
(T
KW
= 10°C / T
WW
= 40°C / T
SP
= 60°C)
Litres
200
Domestic hot water quantity with reheating at rated
output and 15 l/min at tapping rate
(T
KW
= 10°C / T
WW
= 40°C / T
SP
= 60°C)
Litres
300
400
Short time water quantity in 10 min
3)
Litres
190
210
Electrical system
Energy efficiency according to efficiency guidelines
Max. electric power consumption
(without/with heating circulation pump)
(9)*
W
90
Max. electric power consumption in operating mode
"Standby"
W
3,4
Voltage supply
(8)*
~230 V, 50 Hz
Protection type
(10)*
IP X0B
1)
Reheating with nominal output, flow temp. T
V
= 80°C, starting storage tank temp. T
SP
= 65°C, cold water temp. T
KW
= 10°C, domestic hot water temp. T
WW
= 45°C.
2)
The specific water flow according to EN 625 is the potable water flow with a mean temperature increase of 30 K, which the ROTEX GCU compact is able to deliver
in two consecutive tappings of 10 min duration each with a charging temperature of 65°C. A delay of 20 minutes between the two draw-off procedures is usually
assumed. The ROTEX GCU compact reaches this value also with shorter waiting periods.
3)
Reheating with nominal output, starting storage tank temp. T
SP
= 60°C, cold water temp. T
KW
= 10°C, domestic hot water temp. T
WW
= 40°C.
*
Position numbers see fig. 12-1
Tab. 12-1 Technical data ROTEX GCU compact 3xx
Содержание GCU compact