Troubleshooting 24
Index:
1. Indoor or Outdoor DC Fan Motor(control chip is in fan motor)
Power on and when the unit is in standby, measure the voltage of pin1-pin3, pin4-pin3 in fan motor connector. If the
value of the voltage is not in the range showing in below table, the PCB must has problems and need to be replaced.
No.
Color
Signal
Voltage
1
Red
Vs/Vm
192V~380V
2
---
---
---
3
Black
GND
0V
4
White
Vcc
13.5-16.5V
5
Yellow
Vsp
0~6.5V
6
Blue
FG
13.5-16.5V
2.Indoor DC Fan IPM Board (Duct and Ceiling-floor Unit)
Power on and when the unit is in standby, measure the voltage of CON1, pin1-pin2 and pin3-pin2 of CN1 in DC motor
driver board. If the value of the voltage is not in the range showing in below tables, the indoor main PCB must has
problems and need to be replaced.
CON2
CN1
CON1
FAN1
IPM for DC
Fan
EEPROM
Drive Chip
CN2
Rectifier
Содержание ANERU Series
Страница 2: ......
Страница 5: ......
Страница 6: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions...
Страница 12: ...Contents 1 Model Reference 2 2 External Appearance 3 Model Reference...
Страница 15: ...Model Reference 4 2 2 Outdoor Unit Single Fan Outdoor Unit Double Fan Outdoor Unit...
Страница 18: ...IDU Console 3 2 Dimensional Drawings 16 Drain pipe Hanging arm 195 700 600 210...
Страница 21: ...IDU Console 6 6 Air Velocity and Temperature Distributions Discharge Angle 60...
Страница 36: ...IDU Compact Cassette 4 2 Dimensional Drawings...
Страница 38: ...IDU Compact Cassette 6 4 Service Place...
Страница 41: ...IDU Compact Cassette 9 Heating airflow velocity distributions Heating temperature distributions...
Страница 43: ...IDU Compact Cassette 11 Heating airflow velocity distributions Heating temperature distributions...
Страница 45: ...IDU Compact Cassette 13 Heating airflow velocity distributions Heating temperature distributions...
Страница 47: ...IDU Compact Cassette 15 Heating airflow velocity distributions Heating temperature distributions...
Страница 56: ......
Страница 115: ...IDU Super Slim Casstte 54 36k 42k 48k 55k...
Страница 118: ......
Страница 131: ...IDU Duct 7 6 Fan Performance 12K...
Страница 132: ...IDU Duct 8 18K...
Страница 133: ...IDU Duct 9 24K...
Страница 134: ...IDU Duct 10 30K 36K...
Страница 135: ...IDU Duct 11 42K 48K...
Страница 136: ...IDU Duct 12 55K...
Страница 165: ...IDU Duct 41 12k 18k 24k 30k...
Страница 166: ...IDU Duct 42 36k 42k 48k 55k...
Страница 178: ......
Страница 179: ...35mm 1 38in...
Страница 180: ......
Страница 256: ...IDU Floor Ceiling 82 36k 48k 55k...
Страница 259: ......
Страница 267: ...Outdoor Unit 3 Panel Plate B30...
Страница 268: ...Outdoor Unit 4 Panel Plate BA30...
Страница 269: ...Outdoor Unit 5 Panel Plate CA30...
Страница 270: ...Outdoor Unit 6 Panel Plate D30...
Страница 271: ...Outdoor Unit 7 Panel Plate X230...
Страница 272: ...Outdoor Unit 8 Panel Plate X330...
Страница 273: ...Outdoor Unit 9 Panel Plate X430...
Страница 274: ...Outdoor Unit 10 Panel Plate E30...
Страница 275: ...Outdoor Unit 11 Panel Plate 590...
Страница 276: ...Outdoor Unit 12 2 Service Place...
Страница 285: ...Outdoor Unit 21 UO70Xo UO90Xo UO100Xo UO100Xo3F...
Страница 286: ...Outdoor Unit 22 UO120Xo UO140Xo UO160Xo...
Страница 291: ......
Страница 292: ......
Страница 293: ......
Страница 294: ......
Страница 295: ...Outdoor unit printed circuit board diagram 17122000044714 17122000048121 17122000046453...
Страница 297: ...Outdoor unit printed circuit board diagram 17122000048064...
Страница 299: ...Outdoor unit printed circuit board diagram 17122000047742 1 3 4 6 8 9 5 7 10 12 11 2 13...
Страница 302: ...Outdoor unit printed circuit board diagram 17122000041841...
Страница 304: ...Outdoor unit DC motor driver board diagram 17122000021912 5 6 1 2 3 4...
Страница 320: ...3 IDU Installation Duct Connector Connector...
Страница 352: ...Product Features 13 Remote LCD Screen Indicators...
Страница 549: ......
Страница 550: ......
Страница 551: ......
Страница 552: ...email info rotenso com www rotenso com INSTALLER STAMP...