SuperGuard and Piguard Plus
|
1.09
48
10.2 Sensors Layout
In this screen, define the temperature and humidity sensors.
ANALOG INPUT #01
OPTIONS
Temp-1
Temp-2
Temp-3
Temp-4
Humidity
IN
NONE
NONE
OUT
YES
IN / NONE
IN / NONE
IN / NONE
IN / OUT/NONE
NO / YES
The Sensor Layout accommodates up to- four temperature sensors and one humidity sensor. Three can
be defined for use inside the house and up to one can be used out of the house. Mark "IN" for a
temperature sensor connected in the house and OUT for a temperature sensor outside of the house.
NOTE:
Only Sensor Number 4 can be designated as 'Out'.
10.3 Digital Input
•
DIGITAL INPUT #01
Input-1
Input-2
Input-3
Water
Feed
None
AUX. ALARM
: When SuperGuard begins to function, a digital input signal is transmitted to ensure that
the alarm is actually on; if not the alarm starts.
10.4 Analog Output
In this screen, set the analog outputs to one of the following:
•
Variable Heat (up to 2)
•
Variable Fan (up to 4)
•
Damper (up to 4)
ANALOG OUTPUT #01
# FUNCTION 0% 100%
1 Var. Heat 1 0.0 10.0
2 Var. Heat 2 0.0 10.0
3 Var. Fan 1
4 Var. Fan 2
5 Var. Fan 3