SuperGuard and Piguard Plus
|
1.09
Total Rooms
Set the number of Piguard Pluses connected to the Super Guard (10
maximum). Define the Piguard' numbers in a sequential order without skipping
digits. For example: 1, 2, 3, 4... If not set this way, the SuperGuard does not
detect any Piguard Pluses. After defining the number of Piguard Plus
controllers, the SuperGuard begins a search to find the controllers defined.
Language
Select language.
Temperature unit
Select Celsius or Fahrenheit.
Pressure
Select between: Milibar, IN.W.C, Pascal, CM.W.C, and MM.W.C.
Other Units
Select meter or imperial units. Controls the speed and rain flow. Units for
speed are meter/h or mile/h and for rain millimeter/h or inch/h.
Out Temp
Set the outside temperature.
Time
Set clock time.
Password
Set passwords to protect data.
NOTE:
The last six parameters apply to all Piguard Plus units.
4.5 Main Menu
The complete SuperGuard main menu structure is described in the table below:
1 CONTROL
2 DEVICE
3 MANAGEMENT
4 HISTORY
5 CALIBRATION
6 INSTALLATION
1. TEMP
CURVE
1. VENT
LEVELS
1. ANIMAL INV.
1. EMP
1. TEMP
1. RELAY LAYOUT
2. MIN/MAX
LEVEL
2. VAR. FAN
LEVELS
2. DAY GROUP
2. HUM
2. HUM
2. SENSORS
LAYOUT
3. HUMIDITY
3. CURTAIN
LEVELS
3. ALARM SETTING
3. WATER
3. PRESSURE
3. DIG. INPUT
4. STATIC
PRESSURE
4. CIRCULATION
FANS
4. ALARM RESET
4. FEED
4. WATER & FEED
4. AN. OUTPUT
5. SYSTEM
PARAM
5. COOL PAD
5. VERSION
5.
MORTALITY
5. VAR. SPEED FAN
6. CONTROL
MODE
6. FOGGERS
6. READ FROM
6. HEATER
6. SENSOR DEF
7. LIGHT
7. WRITE TO
7. ALARM
7. CURTAIN SETUP
8. FEED
8. EVENT
8. COMM TEST
9. EX. SYS.
9. FAN AIR
CAPACITY
10. TIME
CLOCKS
11. VAR. HEAT