SuperGuard and Piguard Plus
|
1.09
4.2 SuperGuard Main Screen
TEMP 27.1
ROOM #01
RH% 75.0
DAY 1
OUT 24.0
Hr. 13:21
TRGT 80.0
LEVEL 1
NOTE:
The main screen shows basic information regarding rooms controlled by the SuperGuard,
depending on what equipment is plugged in. Other parameters like static pressure (PRESS),
outside temperature (OUT), level, message and offset are also shown on the main screen
when they are plugged in. Parameters are shown according to priority. There is a square in
level line indicating tunnel level.
TEMP
Current room temperature
RH%
Current room humidity
OUT
Outside Temp
TRGT
Target temperature
ROOM #01
Room number
DAY
Growth day
Hr.
Time
LEVEL
Current ventilation level
CAUTION
In case of an alarm, a blinking message appears on the main screens in
addition to the siren. Pressing "0" on the main screen, when the alarm
message is on, directs you to the room with the alarm. Resetting the alarm is
possible, but it only stops the siren and not the screen message. Only by
fixing the problem stops the message.
Pressing the zero on the numeric pad, while the alarm is activated opens the room status screen.
•
An empty square indicates that the SuperGuard identifies the houses correctly.
•
A filled square indicates an alarm is on.
•
A dotted square indicates that there is no communication with the
Piguard Plus.
NOTE:
Once communication is off there is no history accumulation in the SuperGuard.
•
A dotted lined square indicates N/A (not available).
N/A
O.K
No com.
1 2 3 4 5 6 7 8 9 10
Alarm