![Rossum ASSIMIL8OR Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/rossum/assimil8or/assimil8or_operation-manual_1489498034.webp)
34
|
Manual Adjustment
You can also navigate
to each voltage field and adjust it with
the
DATA 2
knob or the encoder. When
adjusting a voltage, it can not be made
greater than the value above it or less than
the value below it, so you may need to
make some iterative adjustments to get
exactly what you want.
Deleting Zones
To delete an existing zone, highlight the
zone’s sample name, click the encoder to
bring up the
Select Sample
window and
rotate the encoder counterclockwise until
“- -“
is displayed. Click the encoder. The zone
will be deleted, the higher numbered zones
will move up fill in the blank spot, and the
deleted zone’s voltage range will be added to
the range of the next higher numbered zone.
All zones above the deleted zone (i.e., lower
numbered zones) are unaffected.
Again, an example might be helpful:
Before deletion:
Zone 1
: +5.0V to 0V
Zone 2:
0V to -2.5V
Zone 3:
-2.5V to -3.75V
Zone 4:
-3.75V to -4.37V
Zone 5:
-4.37V to -5.0V
After deleting the original
Zone 3:
Zone 1:
+5.0V to 0V
Zone 2:
0V to -2.5V
Zone 3:
-2.5V to -4.37V
Zone 4:
-4.37V to -5.0V
i.e., The original
Zones 4
and
5
have now
moved up to be the new
Zones 3
and
4.
The
new
Zone 3
has annexed the old
Zone 3’s
range of -2.5V to -3.75V, leaving
Zones 1, 2,
and
4
(the previous
Zone 5
) unaffected.
Gate Rise vs Continuous Modes
As mentioned above, you can specify if zone
switching happens only on a trigger or gate
rise, or instantly as soon as the controlling CV
crosses a selection boundary.
Here’s how that works:
Gate Rise Mode
In
Gate Rise Mode,
each
time a channel receives a gate rise or
trigger (or its channel button is pressed),
the zone selection CV value is read and
the zone associated with that value
is triggered. Changes to the CV value
between triggers have no effect.
Continuous Mode
In
Continuous
Mode,
the zone selection CV value is
continuously monitored and a new zone is
selected as soon as the CV value indicates.
NOTE:
In
Continuous Mode,
the new zone
starts at the time position corresponding
to the point in the first zone where the switch
happens. E.g., If 2 seconds into the
Zone 1
sample you switch to the
Zone 2
sample, the
Zone 2
sample starts at its 2 second position.
This works best if all samples are the same
length or the channel is set to latch (i.e. repeat
continuously).
If you switch to a new zone that has passed
its end point (because it’s shorter than the
zone it’s transitioning from and is not set to
loop), playback will stop.
Содержание ASSIMIL8OR
Страница 67: ...67...