C5.6
©
ROSS
CONTROLS
®
.
All Rights Reserved.
IMPORTANT NOTE:
Please read carefully and thoroughly all of the
CAUTIONS, WARNINGS
on the inside back cover.
Online Version
02/19/20
Closed Center
Open Center
Power Center
1
2
3
4
5
12
14
1
2
3
4
5
12
14
1
5 3
4 2
12
14
1.97
(50)
3.18 (81)
2.25 (57)
7.68 (195)
2.61
(66)
2.63
(67)
3.94 (100)
2.43
(62)
8.80 (224)
3.57
(91)
3.46
(88)
4.80 (122)
2.50 (63)
9.79 (249)
3.96
(101)
3.90
(99)
7.07 (180)
2.50 (63)
12.06 (306)
3.97
(101)
5.57
(141)
11.43 (290)
2.50 (63)
16.42 (417)
4.08
(404)
ANSI Size 1
ANSI Size 2.5
ANSI Size 4
ANSI Size 10
ANSI Size 20
Double Solenoid Pilot Controlled Valves
ANSI
W70 Series
Options: Indicator Light (in Base/Manifold), refer to page C5.17-C5.18. Accessories ordered separately, refer to page C5.19.
Valve Dimensions –
inches (mm)
5-Way 3-Position Valves
ANSI
Size
Port Size
Valve Model Number
#*
Avg.
C
V
Average Response Constants
**
Weight
lb (kg)
Power Center
Closed Center
Open Center
M
F
In-Out
Out-Exh.
1
1/8 - 3/8 W7077B2906
W
W7077B2331
W
W7077B2332
W
1.0
20
3.5
4.9
4.0 (1.8)
2.5 3/8 - 1/2 W7077A3904
W
W7077A3331
W
W7077A3332
W
2.5
10
1.6
2.6
4.0 (1.8)
4
1/2 - 3/4 W7077C4939
W
W7077D4331
W
W7077D4332
W
4.2
12
0.6
0.7
6.5 (2.9)
10
3/4 - 1
1/4
W7077A6920
W
W7077C6331
W
W7077C6332
W
10
20
0.3
0.3
8.5 (3.8)
20
1
1/4
- 1
1/2
W7077A8901
W
W7077C8331
W
W7077C8332
W
22
30
0.1
0.2
15.3 (6.9)
#
Voltage:
W
=24 VDC;
Z
=100-110/50, 100-130/60 VAC/Hz, e.g., W7077B2906
Z
. For other voltages, consult ROSS.
*
Sub-bases and manifold bases ordered separately, refer to page C5.14-C5.18.
**
Valve Response Time –
Response Time (msec) = M + (F • V). This is the average time required to fill a volume V (cubic
inches) to 90% of supply pressure or to exhaust it to 10% of supply pressure. M and F values are shown above.
STANDARD SPECIFICATIONS
(for valves on this page)
:
Construction Design
Spool and Sleeve
Mounting Type
Base
Solenoids
Rated for continuous duty
Voltage
24 volts DC; 100-110/50, 100-130/60 volts AC/Hz
Power Consumption
(each solenoid)
ANSI
Size 1:
5 watts on DC; 10 VA inrush, 24 VA holding on 50 or 60 Hz
ANSI
Size 2.5, 4, 10 & 20:
14 watts on DC;
87 VA inrush, 55 VA
holding on 50 or 60 Hz
Temperature
Ambient:
40° to 120°F (4° to 50°C)
Media:
40° to 175°F (4° to 80°C)
For other temperature ranges, consult ROSS.
Flow Media
Filtered air
Pilot Supply
Internal or External
Operating Pressure
Vacuum to 150 psig (10 bar)
Pilot Supply - Internal or External:
ANSI Size 1 & 20:
Minimum 30 psig (2 bar)
ANSI Size 2.5, 4 & 10:
Minimum 15 psig (1 bar)
When external pilot supply, pressure must be equal to or greater
than inlet pressure.
Indicator Light
Included for ANSI Size 4, 10 & 20 only
Construction Material
Valve Body:
Cast Aluminum
Spool:
Stainless Steel
Seals:
Buna-N
Manual Override
Flush; Rubber, non-locking
C5
C
Содержание W70 Series
Страница 1: ...Product Information ROSS CONTROLS ANSI Valves W70 Series...
Страница 16: ......
Страница 17: ......
Страница 18: ......