Ross Abekas AirCleaner ACL-A Скачать руководство пользователя страница 7

Overview

AirCleaner

®

is a solid-state, all-digital video and audio

delay machine for use in live-to-air television broadcasts.
AirCleaner

®

is designed as a protection against "wardrobe

malfunctions", spoken profanities, or any type of
unwanted broadcast content. AirCleaner

®

offers multiple

operating modes with the ability to mask video offenses
with an auxiliary safe video source or a defocused live
image. AirCleaner

®

will mask audio offenses with an

auxiliary safe audio source or a mute.

AirCleaner

®

can be operated with either one or two

screeners (operators that censor the live audio/video
feed). In the case of two-screener operation, the total
program delay internal to AirCleaner

®

can be divided

between the two users (in any proportion desired).

AirCleaner

®

operates in either High-Definition (HD) or

Standard-Definition (SD) digital video, with all of the
popular video formats supported. AirCleaner

®

is equipped

with 2 SD/HD SDI video inputs, 2 SD/HD SDI video
outputs and has 1 analog reference input. AirCleaner

®

handles 8 channels (4 stereo pairs) of AES/EBU audio
for each of the 2 video I/O streams. AirCleaner

®

can also

utilized embedded audio in the SDI I/O streams.

Note:

In SD 525 and 625 operation, AirCleaner

®

supports only

4-track (2 stereo pairs) of embedded digital audio, as defined by
SMPTE specification.

AirCleaner

®

also features a single stereo analog audio

monitoring output on a 3.5mm jack.

AirCleaner

®

comes in four configurations:

ACL-A

— Max Delay 5sec(HD), 34sec(SD)

ACL-B

— Max Delay 10sec(HD), 68sec(SD)

ACL-C

— Max Delay 35sec(HD), 68sec(SD)

ACL-D

— Max Delay 70sec(HD), 68sec(SD)

Options

All AirCleaner

®

models support the Redundant Power,

Panic Button Control Panel, and Panel Button Y Cable
options.

Redundant Power Supply

This option provides an additional power supply to guard
against complete system failure in the event of a single
power supply failure. Both power supplies operation in
a load sharing configuration but AirCleaner

®

will run on

a single power supply. In the event that one of the power
supplies fails, the remaining operational power supply
will automatically take over the complete power load.

Panic Button Control Panel

The Panic Button Control Panel provides a simple
two-button interface (one button for Video, the other for
Audio) that sits on a desktop and is connected to the
AirCleaner

®

chassis via a DB9 cable.

The Panic Button Control Panel is used to trigger the
video and/or audio mask in the event of a visual or aural
offense. Pressing the specific button (

AUDIO

or

VIDEO

)

will tell AirCleaner

®

to mask the content according to

how the AirCleaner

®

is programmed. The masking will

continue for the duration the button is held down.

The Panic Button Control Panel communicates to the
AirCleaner

®

chassis over a standard GPI connection. The

Panic Button Control Panel ships with a 33-foot shielded
cable for connection to the GPI connector on the
AirCleaner

®

chassis.

Panic Button Control Panel Y-Cable

AirCleaner

®

can be operated in a two screener mode that

requires a second Panic Button Control Panel. This
customized Y-cable is required to connect two Panic
Button Control Panels to the AirCleaner

®

chassis. The

Y-cable is connected to the rear of the AirCleaner

®

chassis and then the control cables for each of the two
Panic Button Control Panels are connected to the Y-cable.

Abekas AirCleaner User Manual (v3.5) — Overview •

7

Содержание Abekas AirCleaner ACL-A

Страница 1: ...Abekas AirCleaner User Manual v3 5...

Страница 2: ...Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethics hangs on the wall of all Ross Vi...

Страница 3: ...ce with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user w...

Страница 4: ...and voltages that are exposed on the module receptacle connector inside the chassis Please keep fingers tools and foreign metal objects away from the exposed receptacle connector while the chassis ha...

Страница 5: ...ness hours eastern standard time technical support personnel are available by telephone Outside of normal business hours and on weekends a direct emergency technical support phone line is available If...

Страница 6: ...n Time 15 Trigger Stretch 15 Video Setup 16 Video Connections 16 Supported Video Formats 16 To Set the Video Reference Type 16 Audio Setup 17 Audio Connections 17 To Select the Audio Source for PGM IN...

Страница 7: ...D Options All AirCleaner models support the Redundant Power Panic Button Control Panel and Panel Button Y Cable options Redundant Power Supply This option provides an additional power supply to guard...

Страница 8: ...at In this example AirCleaner is programmed with the following parameters Screeners One Total PGM Delay 40 00 Video Reaction 1 2 00 On Video Trigger Defocus Defocus Ramp 0 00 This example begins at an...

Страница 9: ...irst frame that was marked as the start of the violation is just one second away from triggering the system Time 44 00 One second later the first frame of the violation has arrived at the trigger poin...

Страница 10: ...er another second the panic button release marker has reached the trigger point and if a defocus is being applied the real time defocus engine starts to fade out Time 53 00 One second later the aux in...

Страница 11: ...enu User Memory Menu each allowing quick access to specific areas of system configuration or control When you exit the Options Menu or User Memory Menu you are taken back to the first item on the Main...

Страница 12: ...the PGM IN BNC AUX Video IN audio video outputs are locked to the SDI video signal present on the AUX IN BNC Bi Lvl REF IN audio video outputs are locked to the Bi Level sync analog video signal pres...

Страница 13: ...orted All screeners share the total delay time provided by the system 1 Use the SELECT knob to select Screeners 2 Use the SET to select the number of screeners One the total program delay is applied t...

Страница 14: ...usts the offset applied to the audio relative to video in tenths of a second to correct synchronization errors 1 Use the SELECT knob to select PGM Audio Offset 2 Use the SET knob to select the amount...

Страница 15: ...he Audio panic button To Set the Audio Reaction Time This allows the system to compensate for the amount of time it takes for a screener to hear a violation and press the panic button The inpoint for...

Страница 16: ...system switches to when the video panic button is pressed The system can be set to use a defocus instead of the aux video The embedded audio from this video source can also be used TAP OUT the monitor...

Страница 17: ...GM In AES the 4 PGM IN AES audio BNCs SDI Embedded the embedded audio in the PGM IN SDI video signal on the PGM IN BNC 4 Use the SELECT knob to select Save Changes and press the SET knob to select OK...

Страница 18: ...lding the video panic button you can adjust the amount of defocus 4 Defocus Only Use the SELECT knob to select Defocus Ramp a Use the SET knob to select the amount of time to fade the defocus effect i...

Страница 19: ...ob to select the memory register you want to save the setup to 3 Press SAVE and OK to save the setup to the selected memory register 4 Use the SELECT knob to select Finished and press the SELECT knob...

Страница 20: ...ur facility Note The AirCleaner does not support DHCP 1 Open a web browser and navigate to the IP address of the AirCleaner 2 Enter the new network settings in the IP Address Subnet Mask and Gateway f...

Страница 21: ...e settings when the system left the factory 1 From the Main Menu use the SELECT knob to select Options Menu and press the SET knob 2 Use the SELECT knob to select Factory Defaults and press the SET kn...

Страница 22: ...on HD SMPTE 292M 10 bit at 1 5Gb s serial digital Video Inputs SDI SD SMPTE 259M 10 bit at 270Mb s serial digital Value Specification HD 16 Tracks AES EBU 48kHz at 24 bit 8 Tracks 4 stereo pairs per P...

Страница 23: ...Manual Bypass Switch 5 Tally 1 Manual Bypass 6 Tally 2 External Lamp 7 Tally Common 8 Ground 9 Pins 5 Bypass Button and 1 Tally 1 are tied to the Manual Bypass button on the front of the AirCleaner ch...

Страница 24: ...tions 20 O Operating Temperature 22 Operation 8 Options 7 Overview 7 P Panic Button 18 Panic Button Control Panel Y Cable 7 PGM IN 16 PGM IN Audio 17 PGM OUT 16 PGM OUT Audio 17 R Reaction Time Settin...