Video Reference
AirCleaner
®
accepts either Bi-Level or Tri-Level analog
reference. SD video signals can only be locked to a
Bi-Level external reference signal (or to the video input
or free run). HD video signals can be locked to either
Tri-Level or Bi-Level reference, as long as the frame rate
of the video and the reference signal are matched.
The reference signal will lock both the PGM OUT and
TAP OUT together in time with the reference signal. The
reference input is internally terminated (no loop-thru).
Reference can also be set to lock to the PGM IN or AUX
IN video signal or set to free run.
The input video format must be at the same frame-rate
as the input reference signal.
To Set the Video Reference Type
All audio/video outputs from the system will be locked
to the reference source.
1.
From the
Main Menu
, use the
SELECT
knob to
select
Options Menu
and press the
SET
knob.
2.
Use the
SELECT
knob to select
Genlock
.
3.
Use the
SET
knob to select the reference type you
want to use.
•
Free Run
— audio/video outputs are not locked
to any reference signal.
•
PGM Video IN
— audio/video outputs are
locked to the SDI video signal present on the
PGM IN BNC.
•
AUX Video IN
— audio/video outputs are
locked to the SDI video signal present on the
AUX IN BNC.
•
Bi-Lvl REF IN
— audio/video outputs are
locked to the Bi-Level sync analog video signal
present on the REF IN BNC.
•
Tri-Lvl REF IN
— audio/video outputs are
locked to the Tri-Level sync analog video signal
present on the REF IN BNC.
4.
Use the
SELECT
knob to select
Save Changes
and press the
SET
knob to select
OK
.
To Adjust Video Timing
You can adjust the timing of the output video for both
the PGM OUT and TAP OUT.
1.
From the
Main Menu
, use the
SELECT
knob to
select
Options Menu
and press the
SET
knob.
2.
Use the
SELECT
knob to select
H OUT Timing
.
3.
Use the
SET
knob to adjusts the horizontal position
of the PGM OUT and TAP OUT SDI video signals,
in pixels, relative to the reference source. (0 to max)
4.
Use the
SELECT
knob to select
V OUT Timing
.
5.
Use the
SET
knob to adjusts the vertical position of
the PGM OUT and TAP OUT SDI video signals, in
lines, relative to the reference source. (-10 to 10)
6.
Use the
SELECT
knob to select
Pix Vert. Shift
.
7.
Use the
SET
knob to adjusts the vertical picture
position of the PGM OUT and TAP OUT SDI video
signals relative to the reference source. (0 to 50)
8.
Use the
SELECT
knob to select
Save Changes
and press the
SET
knob to select
OK
.