Audio Setup

AirCleaner

®

provides 8 channels of AES/EBU digital

audio on 4 dedicated BNC inputs per video input (PGM
IN, AUX IN) and output (PGM OUT, TAP OUT).
Embedded audio on the video inputs/output is also
supported.

Audio Connections

All AES/EBU digital audio inputs and outputs operate
at the same 48kHz @ 24bit rate. Each BNC supports 2
channels, or a stereo pair.

PGM IN

— the digital audio inputs that are

associated with the PGM IN SDI video input.

PGM OUT

— the delayed "Live to Air" digital audio

output that is associated with the PGM OUT SDI
video output.

AUX IN

— the safe audio feed that the system

switches to when the audio panic button is pressed.
The system can be set to use a mute instead of the
aux audio.

TAP OUT

— the audio out used in a two-screener

work-flow. This audio stream is downstream of the
delay window used by the first screener and allows
the second screener to monitor audio coming into
their own delay window.

A 3.5mm female stereo jack (

STEREO ANALOG

AUDIO OUTPUT

) provides monitoring of analog audio

output. You can monitor any stereo pair from the PGM
OUT audio output. The output level is 0dBmV. The
Analog Audio OUT parameter in the Main Menu controls
the audio source selection for this output jack and the
Analog Audio Vol parameter controls the volume.

To Select the Audio Source for PGM IN

Select the source of the audio that is used for the PGM
In.

1.

From the

Main Menu

, use the

SELECT

knob to

select

Options Menu

and press the

SET

knob.

2.

Use the

SELECT

knob to select

PGM IN Audio

.

3.

Use the

SET

knob to select the audio source for the

PGM In.

AES

— the 4 PGM IN AES audio BNCs.

SDI Embedded

— the embedded audio in the

PGM IN SDI video signal on the PGM IN BNC.

4.

Use the

SELECT

knob to select

Save Changes

and press the

SET

knob to select

OK

.

To Select the Audio Source for AUX IN

Select the source of the audio that is used for the AUX
In.

1.

From the

Main Menu

, use the

SELECT

knob to

select

Options Menu

and press the

SET

knob.

2.

Use the

SELECT

knob to select

AUX IN Audio

.

3.

Use the

SET

knob to select the audio source for the

AUX In.

AES

— the 4 AUX IN AES audio BNCs.

SDI Embedded

— the embedded audio in the

AUX IN SDI video signal on the AUX IN BNC.

4.

Use the

SELECT

knob to select

Save Changes

and press the

SET

knob to select

OK

.

To Configure the Analog Audio Out Jack

You can select the source and audio level that is fed out
of the analog audio headphone jack.

1.

Use the

SELECT

knob to select

Analog Audio

OUT

.

2.

Use the

SET

knob to select the audio source for the

headphones.

PGM OUT 1/2

— monitor program audio

channels 1 and 2.

PGM OUT 3/4

— monitor program audio

channels 3 and 4.

PGM OUT 5/6

— monitor program audio

channels 5 and 6.

PGM OUT 7/8

— monitor program audio

channels 7 and 8.

3.

Use the

SELECT

knob to select

Analog Audio

Vol

.

4.

Use the

SET

knob to select the volume for the

headphones. (0 to 255)

To Embed Audio in the SDI Outputs

You can embed the audio out into the SDI video output
on the PGM OUT and TAP OUT output BNCs.

1.

From the

Main Menu

, use the

SELECT

knob to

select

Options Menu

and press the

SET

knob.

2.

Use the

SELECT

knob to select

Embed. Audio

OUT

.

3.

Use the

SET

knob to select whether the audio is

embedded in the PGM and TAP SDI outputs (

ON

),

or not (

OFF

).

4.

Use the

SELECT

knob to select

Save Changes

and press the

SET

knob to select

OK

.

Abekas AirCleaner User Manual (v3.5) — Audio Setup •

17

Содержание Abekas AirCleaner ACL-A

Страница 1: ...Abekas AirCleaner User Manual v3 5...

Страница 2: ...Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethics hangs on the wall of all Ross Vi...

Страница 3: ...ce with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user w...

Страница 4: ...and voltages that are exposed on the module receptacle connector inside the chassis Please keep fingers tools and foreign metal objects away from the exposed receptacle connector while the chassis ha...

Страница 5: ...ness hours eastern standard time technical support personnel are available by telephone Outside of normal business hours and on weekends a direct emergency technical support phone line is available If...

Страница 6: ...n Time 15 Trigger Stretch 15 Video Setup 16 Video Connections 16 Supported Video Formats 16 To Set the Video Reference Type 16 Audio Setup 17 Audio Connections 17 To Select the Audio Source for PGM IN...

Страница 7: ...D Options All AirCleaner models support the Redundant Power Panic Button Control Panel and Panel Button Y Cable options Redundant Power Supply This option provides an additional power supply to guard...

Страница 8: ...at In this example AirCleaner is programmed with the following parameters Screeners One Total PGM Delay 40 00 Video Reaction 1 2 00 On Video Trigger Defocus Defocus Ramp 0 00 This example begins at an...

Страница 9: ...irst frame that was marked as the start of the violation is just one second away from triggering the system Time 44 00 One second later the first frame of the violation has arrived at the trigger poin...

Страница 10: ...er another second the panic button release marker has reached the trigger point and if a defocus is being applied the real time defocus engine starts to fade out Time 53 00 One second later the aux in...

Страница 11: ...enu User Memory Menu each allowing quick access to specific areas of system configuration or control When you exit the Options Menu or User Memory Menu you are taken back to the first item on the Main...

Страница 12: ...the PGM IN BNC AUX Video IN audio video outputs are locked to the SDI video signal present on the AUX IN BNC Bi Lvl REF IN audio video outputs are locked to the Bi Level sync analog video signal pres...

Страница 13: ...orted All screeners share the total delay time provided by the system 1 Use the SELECT knob to select Screeners 2 Use the SET to select the number of screeners One the total program delay is applied t...

Страница 14: ...usts the offset applied to the audio relative to video in tenths of a second to correct synchronization errors 1 Use the SELECT knob to select PGM Audio Offset 2 Use the SET knob to select the amount...

Страница 15: ...he Audio panic button To Set the Audio Reaction Time This allows the system to compensate for the amount of time it takes for a screener to hear a violation and press the panic button The inpoint for...

Страница 16: ...system switches to when the video panic button is pressed The system can be set to use a defocus instead of the aux video The embedded audio from this video source can also be used TAP OUT the monitor...

Страница 17: ...GM In AES the 4 PGM IN AES audio BNCs SDI Embedded the embedded audio in the PGM IN SDI video signal on the PGM IN BNC 4 Use the SELECT knob to select Save Changes and press the SET knob to select OK...

Страница 18: ...lding the video panic button you can adjust the amount of defocus 4 Defocus Only Use the SELECT knob to select Defocus Ramp a Use the SET knob to select the amount of time to fade the defocus effect i...

Страница 19: ...ob to select the memory register you want to save the setup to 3 Press SAVE and OK to save the setup to the selected memory register 4 Use the SELECT knob to select Finished and press the SELECT knob...

Страница 20: ...ur facility Note The AirCleaner does not support DHCP 1 Open a web browser and navigate to the IP address of the AirCleaner 2 Enter the new network settings in the IP Address Subnet Mask and Gateway f...

Страница 21: ...e settings when the system left the factory 1 From the Main Menu use the SELECT knob to select Options Menu and press the SET knob 2 Use the SELECT knob to select Factory Defaults and press the SET kn...

Страница 22: ...on HD SMPTE 292M 10 bit at 1 5Gb s serial digital Video Inputs SDI SD SMPTE 259M 10 bit at 270Mb s serial digital Value Specification HD 16 Tracks AES EBU 48kHz at 24 bit 8 Tracks 4 stereo pairs per P...

Страница 23: ...Manual Bypass Switch 5 Tally 1 Manual Bypass 6 Tally 2 External Lamp 7 Tally Common 8 Ground 9 Pins 5 Bypass Button and 1 Tally 1 are tied to the Manual Bypass button on the front of the AirCleaner ch...

Страница 24: ...tions 20 O Operating Temperature 22 Operation 8 Options 7 Overview 7 P Panic Button 18 Panic Button Control Panel Y Cable 7 PGM IN 16 PGM IN Audio 17 PGM OUT 16 PGM OUT Audio 17 R Reaction Time Settin...

Отзывы: