Technical description
31 / 89
LCS operation panel
22
RLS lighting head connection
23
Remote start / stop connection (option)
24
USB charging socket connection (option)
25
MAGCODE charging socket connection (option)
26
Three-phase or supply socket (option)
27
RLS lighting head holder (option)
6.2
LCS operation panel
6.2.1
Function switches
ART
ST
(&2
Symbol
Name
Functional description
Start power gener-
ator
The switch activates the control unit after
a short keystroke. The power generator is
started in the event of a longer keystroke.
The switch is backlit for active control
unit.
Stop power gener-
ator
The switch shuts down the power gener-
ator or deactivates the control unit after a
longer keystroke. After 2 minutes the
control unit automatically switches into
Standby mode. The switch is backlit for
active control unit.
Emergency stop
The switch actuates the emergency stop.
If the emergenct stop switch is actuated
the power generator is stopped immedi-
ately.
The switch has two switching positions:
•
Activated: ignition is interrupted -
control of the start relay is prevented
Rotate the switch clockwise, to de-
activate the emergency stop.
•
Deactivated: Normal operation
ECO Mode
(optional)
The switch activates and deactivates the
speed reduction.