background image

- 8 -

Heating

When switched on, the red Heat Indicator light will illuminate and the machine will begin to heat up to 
its optimal temperature.  The initial heating cycle will take 7-10 minutes.  When the green Ready Indica-
tor light comes on, the machine is ready to make fog.  For optimal performance of the Vapour Plus, it is 
recommended that the user wait for the red Heat Indicator to turn off, indicating that the heat exchang-
er has reached its maximum operating temperature, before making fog.  Note:  If no remote is connected 
and no DMX signal is detected, the machine will not heat.

Control Options

There are several methods of controlling the Vapour Plus , including: Manual Control via the Remote 
Control Panel, DMX control via a lighting console and Multi-Link control that allows multiple machines 
to be controlled from a single Remote Control Panel. The Vapour Plus is designed to process large vol-
umes of fluid over short periods of time. At full output the Vapour Plus will make fog for approximately 
60 seconds before stopping to reheat. Longer output durations can be achieved by producing lower fog 
output levels. 
Manual Control via the Detachable Remote Control Panel that is included with each machine.  An op-
erator can control the unit at the machine, or from a distance using the included 3-pin XLR cable.  The  
Remote Control Panel can be used to set fog output volume, power the machine on and off using Stand-
by mode, and set a repeating, timed cycle of on/off operation.
DMX Control from your lighting desk is available as a standard option.  The Vapour Plus will use one 
channel of DMX control for output volume.
Multi-Link allows up to 4 machines to be linked together via 3pin XLR cables (not included) and con-
trolled by a single Remote Control Panel.

Using the Remote Control Panel

The Remote Control Panel can be operated directly on the machine or detached from the unit and used 
at a distance. To detach the Remote Control Panel from the unit, loosen the thumb screws and lift the 
remote from its recessed mount.  A 15 foot (4.5m) cable is provided to allow the machine to be operated 
at a distance.  If needed, a longer 3-pin XLR cable can be used or joined to the existing cable.  Do not 
exceed a maximum distance of 165 feet (50 m) from remote to machine.
When the green Ready Indicator light is illuminated, the Vapour Plus is ready to make fog. For optimal 
performance of the Vapour Plus, it is recommended that the user wait for the red Heat Indicator to turn 
off, indicating that the heat exchanger has reached its maximum operating temperature, before making 
fog.  Press and release the Fog Button to begin producing fog.  The red Power Indicator light will flash 
to indicate the machine is operating. To stop making fog, press and release the Fog Button again. Adjust 
the Fog Level knob to increase or decrease the amount of fog produced.
The Standby Button allows the machine to be “turned off” from the remote without using the Main 
Power Switch.  In Standby mode, the machine will not reheat or make fog, the pump remains unpowered 
and all indicator lights will switch off.  To engage Standby mode, press and release the Standby Button.  
The red Power Indicator light will turn off.  To disengage Standby mode, press and release the Standby 
Button again and the red Power Indicator light will turn back on.  Once Standby mode is disengaged, the 
machine will immediately start heating in preparation to make fog.  Note:  If no remote is connected and 
no DMX signal is detected, the machine will not heat. 
Using Timers
The timer controls allow you to set the machine to produce fog in timed intervals without an operator.  
To engage the timers, press and release the Timer Button.  The green Timer Indicator light will illuminate 
and the machine will begin to produce fog at the level set by the Fog Level Knob, and the red Power 
Indicator light will flash to indicate the machine is operating. 

Содержание Vapour Plus

Страница 1: ...www rosco com Vapour Plus Fog Machine Operating Instructions READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ... 8 Multi Link 8 Using the Remote Control Panel 8 Using Timers 9 Using DMX Control 9 10 Connecting the DMX 9 Setting the DMX Address 9 DMX Operation 10 Using Multi Link 10 Changing Fluid 10 11 Running Dry 11 Priming the System 11 Powering Down 11 Ducting Fog 12 Troubleshooting 12 Maintenance 13 Exterior Cleaning 13 Maintaining the Heat Exchanger 13 Using the Air Input Connection 13 Storage and Ship...

Страница 3: ...herthangenuineRoscofogfluidsastheyhavenotbeentestedforop timal performance and safety considerations Doing so may damage the machine and will void the warranty The RoscoVapour Plus has been tested for use in professional theatrical productions and is included un der the Equipment Based Guidelines of the Equity League Pension and Health Trust Funds The Vapour Plus is also compliant with the Allianc...

Страница 4: ...ny machine that shows signs of improper use Even slight damage may be an indication of a major problem If the machine looks questionable use it only under strict observation If the machine shows any unusual behavior disconnect machine immediately from power and send machine to a Service Center for repair Disconnect unit from power source before servicing and when not in use Preventing Burns and Fi...

Страница 5: ...the machine switched on for prolonged periods of time without producing fog Do Not Enclose the machine Do Not Install the machine in such a fashion that the operator cannot see the whole machine including the indicator lights Do Not Touch the shielded nozzle of the machine Allow sufficient cooling time after operation before attempting to perform maintenance or storage Do Not Direct the fog output...

Страница 6: ...olled from a single Remote Control Panel Main Power Switch Turns unit on or off by controlling the flow of power to the unit Air Input Purge Connection This is a push to connect inlet that accepts OD tubing and allows compressed air to blow through the heat exchanger for cleaning and maintenance Ready Indicator A green indicator light that illuminates when the minimum temperature for producing fog...

Страница 7: ...isabled if Standby mode is engaged Fog Level Knob Rotate to set the desired amount of fog output Higher numbers indicate more fog Output is controlled by pump speed increasing and sending more fog fluid into the heat exchanger Fog On Knob Used only when timer control is engaged Rotate to set the desired time interval that the machine will produce fog During fog production the Power Indicator light...

Страница 8: ... the cap onto the bottle Take precautions to avoid fluid spills All Rosco fog and haze machines are primed at the factory with a small amount of fluid No additional priming should be necessary for proper fog output If fog output is diminished or intermittent see the Priming the System section of this manual for instructions on how to re prime the fluid path Power Connections Ensure that the machin...

Страница 9: ...ly on the machine or detached from the unit and used at a distance To detach the Remote Control Panel from the unit loosen the thumb screws and lift the remote from its recessed mount A 15 foot 4 5m cable is provided to allow the machine to be operated at a distance If needed a longer 3 pin XLR cable can be used or joined to the existing cable Do not exceed a maximum distance of 165 feet 50 m from...

Страница 10: ...our Plus is not a self terminating device a DMX terminator should be used in the DMX OUT port when the unit is the last device in the chain It is not necessary to have the Remote Control Panel attached when controlling the machine via DMX However if no Remote Control Panel is attached and no DMX signal is present the machine will not heat up It is not necessary to send a command via DMX to start t...

Страница 11: ...n XLR cable from the second machine Connect the plug of the cable from the Head Machine into the remote port of the second machine where the Remote Control Panel had previously been connected Repeat this process to connect a third and or fourth machine No additional set up is required The Remote Control Panel attached to the head machine will operate all machines in the Multi Link as if they are t...

Страница 12: ...e nozzle of the machine may remain hot for up to 10 hours after power is shut off If the machine will be unused for an extended period of time follow the Storage and Shipment instruc tions listed under Maintenance to prepare the machine for long term storage DUCTING FOG It is often desirable to duct fog from the machine to another location on stage or in a set This can be accomplished using flexib...

Страница 13: ...kwise or set DMX level between 11 100 Fluid filter above fluid line Ensure filter is submerged Machine requires priming See the Priming the System section of the manual Heat exchanger is clogged Machine produces fog intermittently when Fog Button is not pressed Timer is engaged Turn timers off by pressing Timer Button Green Timer Indicator light should not be illuminated Machine works via the Remo...

Страница 14: ...dically to ensure optimal performance The Air Input Connection was designed to pro vide a fast and efficient method of cleaning the heat exchanger by purging it of residual fluid and build up using compressed air For lasting performance Rosco recommends purging the heat exchanger once a week while in production and before storing the machine for extended periods of time Rosco does not recommend th...

Страница 15: ...0 minutes Control and programming Control options DMX timer remote DMX channels 1 Fluid system Capacity 120v 4 liters 240v 5 litres Fluid consumption 3 6 liters hour Connections DMX 5 pin XLR Remote Multi Link 3 pin XLR AC power Fixed power cable Electrical AC voltage 120V 230V 50 60Hz Main fuse 120V US version 10AT Main fuse 230V EU version 5AT Thermal Maximum ambient temperature 40 C 104 F Exter...

Страница 16: ... 15 15 709 399 17 230 437 65 15 709 399 11 319 287 50 17 230 437 65 15 709 399 17 230 437 65 Dimensions Dimensions are shown in inches and millimeters ...

Страница 17: ...r damage to the Rosco product caused by parts not manufactured distrib uted or certified by Rosco Rosco is not obligated to provide warranty service should the product fail to be properly maintained or fail to function properly as a result of misuse abuse improper installation neglect improper shipping damage caused by disasters such as flood fire and lightning improper elec trical current or conn...

Страница 18: ...1 2007 Generic Immunity Standard for residential and light Industrial environments 60335 1 2002 A15 2011 Safety of household and similar electrical appliances BS EN 62233 2008 Electromagnetic fields These standards reference the following European standards Emissions EN 55 022 B RF voltage and field strength EN61000 3 3 Flicker EN 55 014 RF voltage discontinuous Immunity EN 61000 4 2 Electrostatic...

Отзывы: