13
Unit Operation (Analog, Wheel, Lens)
Mounting
The yoke angle can be adjusted by loosening the tilt knob on both
sides of the unit. In order to slide the yoke back and forth in its track, it
is also necessary to loosen the cap screw at the pivot point. When
loosening the cap screw, it is strongly recommended to do this prior to
hanging the unit to minimize the risk of the unit falling.
The unit can be hung from any C-clamp or other mounting device that
uses a _” bolt. The three holes in the yoke are provided for this
purpose. The use of a safety cable is strongly recommended when
hung overhead. Also make sure not to block the top, bottom, or rear
vents when mounted.
Powering Up
1.
Check to make sure that a lamp is installed.
2.
Make sure the power switch is in the off position and the
hinged lid on the base unit is fully closed. Also make sure the
area in front of the lens is free of combustible materials.
3.
Plug the unit in (check electrical specifications to ensure
compatibility).
4.
Flip the power switch to the on position.
a.
If there are no lights on the rear of the unit, check the
cord and the circuit that the unit is connected to. Also
check the fuse in the unit.
b.
If the control panel lights, but there is no sound or lamp
light indication, check that the lid is fully closed (there
is a safety sensor on the lid).
c.
If the control panel lights, and there is a ticking sound
accompanied by flashing of the lamp indicator, wait 30
seconds, then turn the unit off. Wait a couple minutes,
then try again. If it still does not work, the lamp may
need to be replaced.
d.
If the control panel lights and the lamp indicator comes
on, then the unit is operating properly, but it will take a
couple minutes for the lamp to warm up.
5.
Once the lamp is warmed up, the unit can be adjusted to suit
your needs.
Содержание X-Effects