background image

 

 

PAGE 8 

www.rosco.com 

DIGITAL/DMX  INSTRUCTIONS 

button once. The Language Menu will display. Push an 

ARROW 

button to scroll through the 

language choices. When the desired language is displayed, push the 

ENTER

 button. 

 

9.

 

MANUAL MODE 

To produce fog manually: With the Operation Menu displayed, push the 

RUN

 button or the 

momentary (

MOM

) button located on the remote control. Push the 

RUN

 button again to stop 

producing fog. (The momentary button will stop producing fog as soon as it is released.) The 
volume of fog can be varied by turning the 

JOG WHEEL

 until the desired level is reached. 

The output level is listed in 5% increments on the LCD display. 
 

10.

 

TIMER MODE 

The DIGITAL/DMX REMOTE CONTROL

 

is equipped with timers. To enable the timers: 

With the Operation Menu displaying, push the 

ENTER

 button until the LCD reads 

“SET 

TIMERS”

. Push an 

ARROW 

button until

 “YES”

 is blinking. Push the 

ENTER

 key. The 

LCD will next display the 

ON TIME

 settings. This refers to the amount of time that the 

machine will make fog. The “minutes” display will be blinking. Turn the 

JOG WHEEL

 until 

the desired amount of time is displayed (up to 9 minutes). Next push an 

ARROW 

button and 

the “seconds” display will be blinking. Turn the 

JOG WHEEL

 until the desired amount of 

seconds (up to 59) is displayed. If you want to change the minutes push an 

ARROW 

button 

again. 
 
Once the desired 

ON TIME

 is displayed, push the 

ENTER

 button for the 

OFF TIME

 

setting. This refers to the amount of time between bursts of fog. The “minutes” display will be 
blinking. Turn the 

JOG WHEEL

 until the desired amount of time is displayed (up to 59 

minutes). Next push an 

ARROW 

button and the “seconds” display will be blinking. Turn the 

JOG WHEEL

 until the desired amount of seconds (up to 59) is displayed. If you want to 

change the minutes push an 

ARROW 

button again. 

 
Once the

 OFF TIME

 is set, push the 

ENTER

 button and the LCD will display 

“SET 

DMX?”

. Answer 

“YES”

 if you wish to set a DMX channel (see below 

DMX MODE

) or 

“NO”

 if you do not. Push the 

ENTER

 button. The display will read 

“SAVE SETTINGS?”

If you want to keep the timer settings push an 

ARROW 

button until “

YES”

 is blinking then 

push the 

ENTER

 button. If you do not want to keep the timer settings, push an 

ARROW 

button until “

NO”

 is blinking and then push the 

ENTER

 button. The LCD will return to the 

“SET TIMERS”

 display. New times can now be entered. Once the settings are saved and the 

Operation Menu is displayed, the timer function can be turned on by pushing the 

TIMER

 

button on the remote. The yellow LED over the 

TIMER

 button will light indicating that the 

Delta is in timer mode. When timers are no longer required, simply push the 

TIMER

 button 

again. To adjust the volume in the TIMER MODE, turn the 

JOG WHEEL

 to the desired fog 

volume. 
 

Note:

 When “

YES”

 is chosen in the 

“SAVE SETTINGS”

 submenu, the memory in the 

DIGITAL/DMX REMOTE CONTROL

 

will remember the settings even when the machine is 

turned off or disconnected from a power source. 
 
 
 

11.

 

DMX MODE 

Содержание Rosco Delta 6000

Страница 1: ...ion Manual Revision 1 0 October 2004 ROSCO LABORATORIES INC 52 Harbor View Avenue Stamford CT 06902 USA 800 ROSCONY 203 708 8900 Fax 203 708 8919 email info rosco com Offices Hollywood Toronto London...

Страница 2: ...s manual covers the following products ROSCO DELTA 6000 FOG MACHINE TABLE OF CONTENTS INTRODUCTION 2 HOW THE MACHINE WORKS 2 IMPORTANT SAFEGUARDS 3 GENERAL OPERATING INSTRUCTIONS 5 DIGITAL DMX REMOTE...

Страница 3: ...d always be used together These unique fluid formulations are safe when used according to instructions They are water based and contain no petroleum distillate The operating temperature pump pressure...

Страница 4: ...s use and obtain a cord with a higher current rating Improper extension cords are not only hazardous but may result in poor machine performance due to excessive voltage drop 3 Never use any machine th...

Страница 5: ...ound this equipment or any other electrical device with a heating element 9 The fog should be blown into an open space and should not be directed at people or objects Never blow fog on hot surfaces in...

Страница 6: ...Control The green LED over the POWER button should blink indicating that the Delta is receiving power The Delta 6000 can ONLY operate with a remote control attached Note The remote attaches with stan...

Страница 7: ...rs fluids may cause spitting and serious clogging problems and could result in the production of an unhealthful aerosol The use of other fluids voids the warranty of the Rosco Delta 6000 fog machine 5...

Страница 8: ...id or when there is no DMX signal To view the menu structure see the MENU FLOWCHART on page 18 7 INITIAL OPERATION Follow steps 1 4 above When first powered the DIGITAL DMX REMOTE will display a scrol...

Страница 9: ...push the ENTER button for the OFF TIME setting This refers to the amount of time between bursts of fog The minutes display will be blinking Turn the JOG WHEEL until the desired amount of time is displ...

Страница 10: ...the DMX channel settings push an ARROW button until YES is blinking then push the ENTER button If the DMX channel settings are not to be kept push an ARROW button until NO is blinking Once the DMX ad...

Страница 11: ...ED marked HEATING will light indicating that the Delta is heating up Let the machine warm up until the green READY light is lit Note The ANALOG DMX REMOTE CONTROL will indicate that the fluid containe...

Страница 12: ...andard 5 pin DMX cable to the connection marked DMX IN at the rear of the base unit Note that the DMX signal can pass through to another device by plugging another cable into the DMX OUT plug Note Lik...

Страница 13: ...Delta is heating up Let the machine warm up until the green READY light is lit Note The TIMED REMOTE CONTROL will indicate that the fluid container is low on fluid with a red LED marked LOW FLUID 17 L...

Страница 14: ...ongest time between bursts is 4 minutes By experimenting with the knob the desired time can be determined To turn the timers on push the TIMER button located on the left side of the ANALOG REMOTE A ye...

Страница 15: ...n when handling hot surfaces DO Use the minimum amount of fog required to achieve the desired effect DO NOT Use the machine near a person who has asthma or similar inhalation disorder DO NOT Use any f...

Страница 16: ...ng Soap and water are effective 5 Before and after the machine is stored for an extended period the machine should be properly cleaned The best method for cleaning is using distilled or de ionized wat...

Страница 17: ...154 619 423 1985 800 468 0114 CANADA Rosco Laboratories Ltd 1271 Denison Street 66 Markham Ontario Canada L3R 4B5 905 475 1400 E mail info rosco ca com UNITED KINGDOM Roscolab Ltd Blanchard Works Kang...

Страница 18: ...6000 or the remote controls that have been subject to misuse or accident Neither does the warranty cover any machine that has been opened modified or repaired other than by Rosco or its designated re...

Страница 19: ...NOTE To navigate within a given menu or submenu window i e choosing a language in the Language Menu use the ARROW buttons ENTER YES NO NO ENTER YES NO ENTER ENTER YES ENTER OPERATION MENU LANGUAGE ON...

Страница 20: ...SE 25A 250v REMOTE CONTROLS DIGITAL DMX REMOTE Multi lingual Volume Control Timers On time 0 01 9 59 min Off time 0 01 59 59 min DMX address ANALOG DMX REMOTE Volume Control Timers On time up to 2 00...

Отзывы: