background image

 

 

PAGE 3 

www.rosco.com 

IMPORTANT SAFEGUARDS 

IMPORTANT SAFEGUARDS 

 
READ AND UNDERSTAND THESE SAFETY PRECAUTIONS BEFORE OPERATING 
THE MACHINE. FAILURE TO PROPERLY FOLLOW THESE PRECAUTIONS MAY 
LEAD TO A FIRE, EXPLOSION, OR ELECTRICAL SHOCK. 
 

FOG FLUID HEALTH CAUTION: VAPOR FROM THIS FLUID, LIKE ANY OTHER 
COMMON MATERIAL IN A VAPORIZED STATE, MAY BE IRRITATING TO OR 
CAUSE ALLERGIC SYMPTOMS IN SOME PERSONS WITH ALLERGENIC 
SENSITIVITY. DO NOT EXPOSE AT CLOSE RANGE TO KNOWN ASTHMATICS. 

 
1. This machine uses electrical power at common commercially available voltages. When 
directly contacted, such voltages are hazardous to human life. All precautions commonly 
applicable to the use of electric power generally are applicable to the use of this machine. 
This machine is designed to operate from three-wire power systems where one of the wires is 
a safety ground. DO NOT disconnect the safety ground or use extension cords or "cheater" 
plugs to connect this machine to a two-wire system. Operation without a safety ground may 
result in a hazardous electrical shock. 
 
2. Check the current and voltage rating of your machine. Extension cords must be properly 
sized and rated for voltage, current and length. Check your local electrical code for the correct 
gauge extension cord. If an extension cord shows signs of wear or gets warm to the touch, 
discontinue its use and obtain a cord with a higher current rating. Improper extension cords 
are not only hazardous, but may result in poor machine performance due to excessive voltage 
drop. 
 
3. Never use any machine that shows signs of improper use. Even slight damage may be an 
indication of a major problem. If the machine looks questionable, use it only under strict 
observation. If the machine shows any unusual behavior, disconnect machine immediately 
from power and send machine to a Service Center for repair. 
 
4. Do not operate the machine in a tightly confined space where the ambient temperature 
might exceed 135° F (57° C). A continuous flow of air is required to maintain temperature 
within the machine housing. Sensitive electronic components deteriorate rapidly under high 
heat conditions. Operation of the machine in an enclosure of less than one cubic meter is 
dangerous, and automatically voids the warranty. 
 

Enclosing any heating device so it is invisible to the operator creates a potential fire 
hazard, no matter what the ambient tempearture of the enclosure. To do so with any 
high-amperage device is to assume substantial risk. Rosco strongly recommends against 
it. 

 
5. In any facility, the fog concentration should be controlled. The fog should never mask 
emergency exits, safety signs, staircases or other safety constructions. 
 
6. After long use, or if the machine is not properly set, some liquid droplets or wet area may 
appear in front of the machine’s outlet. This liquid should be wiped up to prevent a condition 
where someone might slip and fall. 

Содержание Rosco Delta 6000

Страница 1: ...ion Manual Revision 1 0 October 2004 ROSCO LABORATORIES INC 52 Harbor View Avenue Stamford CT 06902 USA 800 ROSCONY 203 708 8900 Fax 203 708 8919 email info rosco com Offices Hollywood Toronto London...

Страница 2: ...s manual covers the following products ROSCO DELTA 6000 FOG MACHINE TABLE OF CONTENTS INTRODUCTION 2 HOW THE MACHINE WORKS 2 IMPORTANT SAFEGUARDS 3 GENERAL OPERATING INSTRUCTIONS 5 DIGITAL DMX REMOTE...

Страница 3: ...d always be used together These unique fluid formulations are safe when used according to instructions They are water based and contain no petroleum distillate The operating temperature pump pressure...

Страница 4: ...s use and obtain a cord with a higher current rating Improper extension cords are not only hazardous but may result in poor machine performance due to excessive voltage drop 3 Never use any machine th...

Страница 5: ...ound this equipment or any other electrical device with a heating element 9 The fog should be blown into an open space and should not be directed at people or objects Never blow fog on hot surfaces in...

Страница 6: ...Control The green LED over the POWER button should blink indicating that the Delta is receiving power The Delta 6000 can ONLY operate with a remote control attached Note The remote attaches with stan...

Страница 7: ...rs fluids may cause spitting and serious clogging problems and could result in the production of an unhealthful aerosol The use of other fluids voids the warranty of the Rosco Delta 6000 fog machine 5...

Страница 8: ...id or when there is no DMX signal To view the menu structure see the MENU FLOWCHART on page 18 7 INITIAL OPERATION Follow steps 1 4 above When first powered the DIGITAL DMX REMOTE will display a scrol...

Страница 9: ...push the ENTER button for the OFF TIME setting This refers to the amount of time between bursts of fog The minutes display will be blinking Turn the JOG WHEEL until the desired amount of time is displ...

Страница 10: ...the DMX channel settings push an ARROW button until YES is blinking then push the ENTER button If the DMX channel settings are not to be kept push an ARROW button until NO is blinking Once the DMX ad...

Страница 11: ...ED marked HEATING will light indicating that the Delta is heating up Let the machine warm up until the green READY light is lit Note The ANALOG DMX REMOTE CONTROL will indicate that the fluid containe...

Страница 12: ...andard 5 pin DMX cable to the connection marked DMX IN at the rear of the base unit Note that the DMX signal can pass through to another device by plugging another cable into the DMX OUT plug Note Lik...

Страница 13: ...Delta is heating up Let the machine warm up until the green READY light is lit Note The TIMED REMOTE CONTROL will indicate that the fluid container is low on fluid with a red LED marked LOW FLUID 17 L...

Страница 14: ...ongest time between bursts is 4 minutes By experimenting with the knob the desired time can be determined To turn the timers on push the TIMER button located on the left side of the ANALOG REMOTE A ye...

Страница 15: ...n when handling hot surfaces DO Use the minimum amount of fog required to achieve the desired effect DO NOT Use the machine near a person who has asthma or similar inhalation disorder DO NOT Use any f...

Страница 16: ...ng Soap and water are effective 5 Before and after the machine is stored for an extended period the machine should be properly cleaned The best method for cleaning is using distilled or de ionized wat...

Страница 17: ...154 619 423 1985 800 468 0114 CANADA Rosco Laboratories Ltd 1271 Denison Street 66 Markham Ontario Canada L3R 4B5 905 475 1400 E mail info rosco ca com UNITED KINGDOM Roscolab Ltd Blanchard Works Kang...

Страница 18: ...6000 or the remote controls that have been subject to misuse or accident Neither does the warranty cover any machine that has been opened modified or repaired other than by Rosco or its designated re...

Страница 19: ...NOTE To navigate within a given menu or submenu window i e choosing a language in the Language Menu use the ARROW buttons ENTER YES NO NO ENTER YES NO ENTER ENTER YES ENTER OPERATION MENU LANGUAGE ON...

Страница 20: ...SE 25A 250v REMOTE CONTROLS DIGITAL DMX REMOTE Multi lingual Volume Control Timers On time 0 01 9 59 min Off time 0 01 59 59 min DMX address ANALOG DMX REMOTE Volume Control Timers On time up to 2 00...

Отзывы: