PAGE 10
www.rosco.com
ANALOG/DMX INSTRUCTIONS
ANALOG/DMX REMOTE CONTROL
OPERATING INSTRUCTIONS
OVERVIEW
The ANALOG/DMX REMOTE CONTROL is an analog interface that consists of an array of
switches and knobs. These allow the Delta 6000 base unit to be operated: manually; from
timers; from DMX control; or from a 0-10 volt signal. The timers will allow production of fog
for up to 2 minutes with intervals of up to 4 minutes between bursts. It also has a series of
rotary switches to set the DMX channel. In addition, the ANALOG/DMX REMOTE
CONTROL has LEDs that indicate when the reservoir is running low on fluid or when there
is a DMX signal.
12.
INITIAL OPERATION
Follow steps 1-4 above. When first powered, the red LED marked
“HEATING”
will light
indicating that the Delta is heating up. Let the machine warm up until the green
“READY”
light is lit.
Note:
The ANALOG/DMX REMOTE CONTROL
will indicate that the fluid
container is low on fluid with a red LED marked
“LOW FLUID”
.
13.
LOCAL OPERATION
To produce fog directly from the remote, push the
FOG
switch located on the right side of the
remote control. If the upper part of the switch is depressed, the Delta will produce fog until
the switch is returned to the center position. To create fog momentarily, depress the lower part
of the switch. When the switch is released it will automatically return to the center position.
The volume of the fog can be varied by turning the
FOG VOLUME
knob until the desired
level is reached.
POWER
Button
TIMER
Button
TIMER
LED
POWER
LED
DMX
Rotary Knobs
DMX
LED
FOG
LED
FOG
Switch
ON TIME
Knob
OFF TIME
Knob
VOLUME
Control
ANALOG/DMX REMOTE CONTROL