Device functions
Page 28
RES-5011
Version 2
8.6.9
Standby active (SA)
This bit is active if the RS bit is set. It shows the PLC when the controller has accepted the RS bit or the MP bit,
so that these bits can be reset again (handshake).
8.6.10 Measurement interruption (MU)
This bit is available as from firmware version 303.
This bit is active as long as the controller does not perform a temperature measurement during the regulation
phase (ST = 1). This can occur when the actual value is larger than the setpoint value (setpoint exceeded). This
can be used, for example, to evaluate whether measurement interruptions occur during the heating impulse. This
would then be an indication of excessive temperature, which can result in a bad sealing seam.
As soon as a measurement is performed again, the MU bit goes back to 0.
8.6.11 Actual value
All 16 bits of the first word must be interpreted as a signed number (twos complement notation). The resolution is
1 °C. During the calibration procedure or if a fault occurs, the actual value is 0.
8.6.12 Error codes
If a fault is signaled (AL bit = 1), you can determine the exact cause with the help of the error code. The error code
is contained in the third word at bit positions 0…9 (
section 8.19 "Error messages" on page 63).
8.7
Parameter object (class: 0x0F)
In accordance with the CIP specification, the RES-5011 provides a parameter object containing all of the device
parameters.
All instances of the parameter object support the "Get_Attribute_Single" and "Get_Attribute_All" services. The
class (instance 0) additionally supports the "Save", "Restore", and "Reset" services. The instances additionally
support the "Set_Attribute_Single" service for attribute 1.
The instances 54 to 70 are first available as from firmware 303.
The parameter object has the following structure:
Instance
Attri-
bute ID
Data
type
1
Name
Default
value
Value range
0
(class)
1
UINT
Revision
1
2
UINT
Max. instance
70
6
UINT
Max. class attribute
9
7
UINT
Max. instance attribute
6
8
UINT
Parameter class description
13
9
UINT
Configuration assembly
102
!
!