Device functions
Version 2
RES-5011
Page 21
HEAT
(yellow)
—
START requested but func-
tion blocked (e.g.
AUTOCAL active, set tem-
perature < 40 °C)
START executing
OUTPUT
(green)
In control mode, luminous intensity is proportional to heating current.
ALARM
(red)
Configuration error, no
AUTOCAL possible
Controller calibrated incor-
rectly, run AUTOCAL
Error,
section 8.19
MODULE STATUS
Green: Standby
Red: Warning, e.g. rotary
coding switch setting
changed
Red / green: Self-test
Green: Normal operation
Red: Serious communica-
tion error
NETWORK
STATUS
Green: No connection but
IP address received
Red: Connection timeout
Red / green: Self-test
Green: At least one con-
nection to scanner
Red: IP address of con-
troller already assigned
LINK PORT 1, 2
(green)
—
—
Connection exists to
Ethernet
RX / TX PORT 1, 2
(yellow)
Device is transmitting / receiving Ethernet frames
LED
Blinks slowly (1 Hz)
Blinks fast (4 Hz)
Lit continuously