Device functions
Version 5
UPT-6011
Page 48
69
1
UINT
Calibration resistance, channel 6
(in 0.1 m
)
0 m
0…65535
(0…6553.5 m
)
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 45 30 01
4
WORD
Descriptor
0x0014 (scaling supported)
5
USINT
Data type
0xC7
6
USINT
Data length
2
13
USINT
Factor
1
14
USINT
Divisor
10
15
USINT
Basis
1
16
USINT
Offset
0
70
1
UINT
Calibration resistance, channel 7
(in 0.1 m
)
0 m
0…65535
(0…6553.5 m
)
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 46 30 01
4
WORD
Descriptor
0x0014 (scaling supported)
5
USINT
Data type
0xC7
6
USINT
Data length
2
13
USINT
Factor
1
14
USINT
Divisor
10
15
USINT
Basis
1
16
USINT
Offset
0
71
1
UINT
Initial calibration resistance,
channel 0 (in 0.1 m
)
0 m
0…65535
(0…6553.5 m
)
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 47 30 01
4
WORD
Descriptor
0x0014 (scaling supported)
5
USINT
Data type
0xC7
6
USINT
Data length
2
13
USINT
Factor
1
14
USINT
Divisor
10
15
USINT
Basis
1
16
USINT
Offset
0
Instanc
e
Attri-
bute
ID
Data
type
1
Name
Default
value
Value range