Device functions
Version 5
UPT-6011
Page 40
33
1
SINT
Calibration temperature, channel 6
20 °C
-1 (= variable),
0…40 °C
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 21 30 01
4
WORD
Descriptor
0x0000
5
USINT
Data type
0xC2
6
USINT
Data length
1
34
1
UINT
Correction factor, channel 6
100
25…200%
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 22 30 01
4
WORD
Descriptor
0x0000
5
USINT
Data type
0xC7
6
USINT
Data length
2
35
1
UINT
Temperature coefficient, channel 6
1700 ppm/K
400…4000 ppm/K
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 23 30 01
4
WORD
Descriptor
0x0000
5
USINT
Data type
0xC7
6
USINT
Data length
2
36
1
SINT
Calibration temperature, channel 7
20 °C
-1 (= variable),
0…40 °C
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 24 30 01
4
WORD
Descriptor
0x0000
5
USINT
Data type
0xC2
6
USINT
Data length
1
37
1
UINT
Correction factor, channel 7
100
25…200%
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 25 30 01
4
WORD
Descriptor
0x0000
5
USINT
Data type
0xC7
6
USINT
Data length
2
Instanc
e
Attri-
bute
ID
Data
type
1
Name
Default
value
Value range