3. Install the supply pipework to the isolation valve and the brass manifolds. The hot water feed should
be installed into the left hand manifold and the cold water feed to the right hand manifold. Ensure the
isolation valves are mounted so that they will be visible and accessible for later stages (Figure 2).
4.With the water inlet supplies installed, install outlet pipework using suitable plumbing fittings. Outlet 1
is intended to be used for shower handset options below the valve, with Outlet 2 intended for use with
overhead showers.
Note: If using this valve with a bath filling option, this needs to be connected to Outlet 2. See Step 15 for
a guide on swapping control buttons over.
Figure 2
Brass Manifold
Isolation Valve
H
C
Figure 3
OUTLET 1
These fittings are used with the flexible hoses
to connect the valve to inlets and outlets
OUTLET 2
H
C