16. Position the cover plate over the valve housing and fix in place with the cover plate fixing nut.
Tighten the plate to the wall with the tool provided making sure not to scratch the cover plate. Make
sure the cover plate is level and that the buttons are in line with those on the valve. The cover plate is
fitted with an integrated foam seal - it is not necessary to use silicone sealant. Test that the cover plate
and valve buttons are correctly aligned by testing the button operation.
You are now ready to install the cover plate and valve controls.
15. The cover plate is supplied with control buttons marked for a shower handset and shower head. A
spare button for a bath filler is also supplied. If you are using a shower handset and shower head, you
do not need to change the button and can proceed to Step 16.
If installing a bath filler to the valve, remove the unused outlet button to be replaced with the bath filler
button. Remove the brass button fixing nut on the back of the cover plate. (Figure 14) This will allow the
button to be swapped. Ensure the springs are positioned on the button pins upon reassembly.
Figure 14
Figure 15
Button Fixing Nut
Springs