ROOTS RootsScrub E430 Скачать руководство пользователя страница 7

7

RootsScrub E430

All paragraphs in this manual referring to you personal safety, 
the safety of your machine and the environmental protection 
are attributed one of the following warning symbols:

Safety  provisions  in  dangerous  situation  caused  by  misuse 
inaccurate adherence of instruction or prescribed work routine.

Safety Provisions

 (persons and goods)

Due  to  use  of  substances  representing  an  inherent  danger  to 
health of environment.

Ecological Hazard

 (the environment)

Prior to first operation, read the manual carefully and strictly 
comply with the instructions contained.

Read Manual

Important  information  on  handling  the  machine  in  order  to 
maintain operability.

Caution

 (the machine)

SAFETY & WARNING SYMBOLS

SAFETY INSTRUCTIONS

Electrical Power Connection Safety Instructions:

DANGER

=

The voltage indicated on the name plate must correspond to 
the voltage of the electrical source.

=

While  working  with  fluids  (such  as  detergents),  we 
recommend  the  use  of  a  safe  socket  with  over  current 
protection.

=

Please use the mains cable authorized by the manufacturer; 
the  same  is  also  applicable  when  you  replace  the  internal 
cables.

=

Check  the  power  cord  with  mains  plug  for  damage  before 
every  use.  If  the  power  cord  is  damaged,  please  arrange 
immediately  for  the  exchange  by  an  authorized  customer 
service or a skilled electrician.

=

Never touch the mains plug with WET hands.

=

Make sure that the power cord or extension cables are not 
damaged  by  running  over,  pinching,  dragging  or  similar. 
Protect the cable from heat, oil, and sharp edges.

=

 I

f couplings of the power cord or extension cable are damaged 

replace  the  splash  protection  and  the  mechanical  tightness 
must be ensured.

=

The power cord must be checked regularly for 
damages, such as cracks or aging. If damage is 
found,  the  cable  must  be  replaced  before 
further use.

Application Safety Instructions:

DANGER

DO NOT CLEAN THE MACHINE WITH A WATER HOSE OR 
HIGH-PRESSURE  WATER  JET  (DANGER  OF  SHORT 
CIRCUITS OR DAMAGE TO MACHINE).

=

The water level indication hose must be cleaned regularly and 
checked for signs of damage.

=

Never  scrub  or  vacuum  up  explosive  liquids,  combustible 
gases, explosive dusts as well as undiluted acids and solvents! 
This  includes  petrol,  paint  thinner  or  heating  oil  which  can 
generate explosive fumes or mixtures upon contact with the 
suction air. Acetone, undiluted acids and solvents must also be 
avoided as they can harm the materials on the machine.

=

Do not scrub or vacuum up any burning or glowing objects.

=

Do not use this machine as a vacuum cleaner.

=

Humans and animals must not be scrubbed/vacuumed with 
this machine.

=

Only use chemicals recommended by the manufacturer and 
comply  with  their  application,  disposal  and  warning 
guidelines.

=

Do not use the recommended detergents in an undiluted state. 
The products are safe for operations as they do not contain 
any acids, alkalis or environment hazardous substances. We 
recommend to keep the detergents out of reach of children. If 
the detergent comes in contact with the eyes, please rinse the 
eyes thoroughly with water, consult a doctor immediately if 
the detergent has been swallowed.

=

This  machine  is  not  suitable  for  vacuuming  dust.  This 
endangers health.

=

Please follow the regulations for disposing off dirty water.

=

This machine is not a vacuum cleaner! Never suck in more fluid 
than what has been sprayed. Do not use to suck in dry dust!

=

This machine must be used only on indoors only.

CAUTION

SAFETY INSTRUCTIONS

Содержание RootsScrub E430

Страница 1: ...1 RootsScrub E430 Operator s Manual RootsScrub E430 Walk Behind Scrubber Drier Electric Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion 230V 50Hz...

Страница 2: ...2 RootsScrub E430...

Страница 3: ...lean Ltd RMCL is not liable for any legal claims that may arise as a direct or indirect result of the contents of this manual RootsMulticleanLtd R K G IndustrialEstate Ganapathy Coimbatore 641006 Indi...

Страница 4: ...Totalweight empty 79kg Totalweight readytooperate 100kg No ofbrushespermachine 1 Brushdiameter 430mm Brushspeed 280rpm Scrubbingwidth 430mm Brushload 22kg Freshwatertank 22L Dirtywatertank 22L Vacuum...

Страница 5: ...with the machine for additional information This Warranty Policy is applicableonlyfortheproductsoldwithinIndia If the product requires repair or maintenance work to be performed please ensure that you...

Страница 6: ...USTOMER SUPPORT SYSTEM ANNUAL MAINTENANCE CONTRACT Customer Support System Process Customer CSS Executive Engineer Site Location AMC or Annual Maintenance Contract is a professional and timely mainten...

Страница 7: ...e the splash protection and the mechanical tightness mustbeensured The power cord must be checked regularly for damages such as cracks or aging If damage is found the cable must be replaced before fur...

Страница 8: ...oriesifattachedmustbedisconnected Switch off the power prior to performing any cleaning or maintenance tasks on the machine replacing parts or switching over to another function In the case of mains o...

Страница 9: ...tion Use only original extension cables with maximum admissiblelengthof25m When using or replacing line cords it is necessary to adhere toasspecifiedbythemanufacturer When replacing coupler plugs of l...

Страница 10: ...icHazard NoSmoking ResetWarning ElectricalHazard DisconnectPowercord Do not let powercord come in contact with waterorotherfluids ElectricShockHazard STOPNoAccess Do Not Use High Pressure Jets General...

Страница 11: ...ergent and the perfect dosage applicable to it will come through sustained use of the machine After unpacking Principle of Operation Beforeoperation 1 Upon delivery the machine has been secured by ins...

Страница 12: ...l B A 1 Switches For Vacuum Motor And Brush A ON OFF switch for Suction Turbine Isonwhen A isatposition I Isoff when A isatposition 0 B ON OFF Switch for Brush Motor Isonwhen B isatposition I Isoff wh...

Страница 13: ...tioned as close as possible over thecenterofthebrush Lower the front end of the machine so that the catch is centeredinthebrush Turnonswitch D forashorttimeinordertoallowlocking Thetankshouldbeempty L...

Страница 14: ...led nuts just slightly by hand has to be done starting from the center towards outside sealing stripswithslotstofrontside andplainonetotherear 1 3 2 2 1 If worn the rear sealing strip can be turned at...

Страница 15: ...ill be useful to clean at first the border areas passing with the machine along those areas incounterclockwisesense Cleaning of the remaining areas then should be effected stripebystripe startingfromt...

Страница 16: ...ty andFreshWaterTanks Cleanthesealingstripsatthesqueegee Check the strainer upstream of the intake opening in the fresh water tank clean if required as otherwise the suction efficiencywillbeaffected T...

Страница 17: ...n replacing any parts shut off the machine and on principle disconnectthepowerplugfromthepowersupply For reasons of safety during cleaning and or maintenance work in or on the tank the tank lid when l...

Страница 18: ...18 RootsScrub E430...

Страница 19: ...9 RootsScrub E430 Roots Multiclean Ltd R K G Industrial Estate Ganapathy Coimbatore 641 006 India Phone 91 422 4330 330 E mail rmclsales rootsemail com Web rootsmulticlean in Toll Free 1800 41 99 77 9...

Отзывы: