ROOTS RootsScrub E430 Скачать руководство пользователя страница 15

15

RootsScrub E430

Ÿ

Fill  fresh  water  and  detergent  as  described  below  before 

start of operation.

Ÿ

Fill the fresh water tank with water (50° max) as required by 

the work to be done, and add detergent as specified by the 
manufacturer.

Use detergents suitable for automatic machines (low foaming) in 
order  to  preclude  damages  at  the  suction  turbine.  We 
recommend  our  agents  for  cleaning  and  care,  which  are 
perfectly  adopted  to  the  machine.  These  products  fulfil  the 
requirements of the Detergents Act.

How to operate the machine:

Filling of water

Dirty And Fresh Water Tanks

Ÿ

Turn on Switch “B” the brush is rotating.

Ÿ

To discharge the detergent, position the lever 

suitably  to  achieve  the  desired  flow  of 
detergent.

Ÿ

Lower the brush head.

Ÿ

Lower the squeegee.

Ÿ

Turn on switch “A” the suction turbine is running.

After  lowering  the  brush  move  the  machine 
immediately; otherwise the brush might leave traces on 
the floor. Lift the squeegee during reverse travel. When 
passing over dormers with a height of more than 0.7° in 
=10 mm, the brush drive must be turned off and the 
brush must be lifted up.

Ÿ

It is dangerous to pass over the power supply cable while the 
brush is rotating. 

Ÿ

Cleaning of floor areas starts from the outlet socket   and is 
effected stripe by stripe.

Ÿ

In case of unoccupied areas it will be useful to clean at  first 
the border areas, passing with the machine along those areas 
in counterclockwise sense.

Ÿ

Cleaning  of  the  remaining  areas  then  should  be  effected 
stripe by stripe, starting from the outlet socket.

Ÿ

Partially  occupied  areas  should  be  subdivided  into  single 
working areas, within reach of the power supply cable. 

Ÿ

Within  a  short  time,  the  operator  will  learn  how  to  avoid 
unnecessary inconveniences caused by the cable.

When work is completed, the dirty water tank has to be 
drained  and rinsed.

Draining of fresh water tank

Ÿ

The water level hose is used to drain the fresh  water.

The tank requires rinsing at regular intervals.

Fresh water
tank

Strainer

Soiled water
tank

Float switch

The machine has a Dirty water tank and a Fresh water 

tank. 

(lye) 

Please do not fill water temperature above 50°C. Do not fill the 
tank  beyond  its  maximum  capacity.  Dirty  water  is  fed  via  the 
suction hose into the dirty water tank.

- Do not collect any external water.
-  When  work  is  finished  both  the  dirty  and  the  fresh 

water tanks on principle must be drained  and  rinsed 
in  order  to  preclude formation of residues.

For disposal of dirty water and lye, the legal provisions 
have  to be compiled with. 
Check the in-feed filter in the tank   regularly and clean it 
if required.

Procedure for draining tanks  

Ÿ

Slowly open the cap and drain the water.

Ÿ

Re-close the cap.

Ÿ

Re-attach the drain hose.

Ÿ

Follow the above sequence to drain the fresh water tank.

Draining of dirty water tank

Ÿ

Is used to drain the dirty water.

PROCEDURE FOR SCRUBBING

Содержание RootsScrub E430

Страница 1: ...1 RootsScrub E430 Operator s Manual RootsScrub E430 Walk Behind Scrubber Drier Electric Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion 230V 50Hz...

Страница 2: ...2 RootsScrub E430...

Страница 3: ...lean Ltd RMCL is not liable for any legal claims that may arise as a direct or indirect result of the contents of this manual RootsMulticleanLtd R K G IndustrialEstate Ganapathy Coimbatore 641006 Indi...

Страница 4: ...Totalweight empty 79kg Totalweight readytooperate 100kg No ofbrushespermachine 1 Brushdiameter 430mm Brushspeed 280rpm Scrubbingwidth 430mm Brushload 22kg Freshwatertank 22L Dirtywatertank 22L Vacuum...

Страница 5: ...with the machine for additional information This Warranty Policy is applicableonlyfortheproductsoldwithinIndia If the product requires repair or maintenance work to be performed please ensure that you...

Страница 6: ...USTOMER SUPPORT SYSTEM ANNUAL MAINTENANCE CONTRACT Customer Support System Process Customer CSS Executive Engineer Site Location AMC or Annual Maintenance Contract is a professional and timely mainten...

Страница 7: ...e the splash protection and the mechanical tightness mustbeensured The power cord must be checked regularly for damages such as cracks or aging If damage is found the cable must be replaced before fur...

Страница 8: ...oriesifattachedmustbedisconnected Switch off the power prior to performing any cleaning or maintenance tasks on the machine replacing parts or switching over to another function In the case of mains o...

Страница 9: ...tion Use only original extension cables with maximum admissiblelengthof25m When using or replacing line cords it is necessary to adhere toasspecifiedbythemanufacturer When replacing coupler plugs of l...

Страница 10: ...icHazard NoSmoking ResetWarning ElectricalHazard DisconnectPowercord Do not let powercord come in contact with waterorotherfluids ElectricShockHazard STOPNoAccess Do Not Use High Pressure Jets General...

Страница 11: ...ergent and the perfect dosage applicable to it will come through sustained use of the machine After unpacking Principle of Operation Beforeoperation 1 Upon delivery the machine has been secured by ins...

Страница 12: ...l B A 1 Switches For Vacuum Motor And Brush A ON OFF switch for Suction Turbine Isonwhen A isatposition I Isoff when A isatposition 0 B ON OFF Switch for Brush Motor Isonwhen B isatposition I Isoff wh...

Страница 13: ...tioned as close as possible over thecenterofthebrush Lower the front end of the machine so that the catch is centeredinthebrush Turnonswitch D forashorttimeinordertoallowlocking Thetankshouldbeempty L...

Страница 14: ...led nuts just slightly by hand has to be done starting from the center towards outside sealing stripswithslotstofrontside andplainonetotherear 1 3 2 2 1 If worn the rear sealing strip can be turned at...

Страница 15: ...ill be useful to clean at first the border areas passing with the machine along those areas incounterclockwisesense Cleaning of the remaining areas then should be effected stripebystripe startingfromt...

Страница 16: ...ty andFreshWaterTanks Cleanthesealingstripsatthesqueegee Check the strainer upstream of the intake opening in the fresh water tank clean if required as otherwise the suction efficiencywillbeaffected T...

Страница 17: ...n replacing any parts shut off the machine and on principle disconnectthepowerplugfromthepowersupply For reasons of safety during cleaning and or maintenance work in or on the tank the tank lid when l...

Страница 18: ...18 RootsScrub E430...

Страница 19: ...9 RootsScrub E430 Roots Multiclean Ltd R K G Industrial Estate Ganapathy Coimbatore 641 006 India Phone 91 422 4330 330 E mail rmclsales rootsemail com Web rootsmulticlean in Toll Free 1800 41 99 77 9...

Отзывы: