RonI, INC
8001 Tower Point Drive
Charlotte, NC 28227
U.S.A.
Toll Free (866) 543-8635
Ph.: (704) 847-2464
Fax: (704) 847-6739
Email:
Web Site: http://www.liftoflex.com
Rev July 2016
13
10 Trouble Shooting
LIFT-O-FLEX
is designed for effective and reliable performance providing the maintenance instructions are
followed. Should problems occur, follow the checklist below. If problems persist, please contact your distributor.
Symptom
Action
1
Motor is not functioning
A
Check the voltage which should be 24 volt.
B
There is a 30 Amp fuse in the power pack
Check the following.
C
Make sure connections with motor are ok.
D
Make sure connections to battery charger and wall
Outlet ok while charging.
E
Make sure the lamp on the battery charger is lit, see
8.1 Charging.
2
The platform does not move,
A
Check above #1.
but motor works.
B
Make sure
Maximum Load Weight
is not exceeded.
C
Make sure the mast is in place. See 5.2 Mounting.
3
The load platform moves slowly.
A
See above #1, Action 1A, 1C, 1D and 1E.
4
The lifting device sounds
A
Check 9. Maintenance.
strange while lifting/lowering.