background image

 

32

 

 

Diagram

 

for

 

electric

 

connection

 

with

 

IR

 

07

 

SOL

 

regulator

 ‐ 

variant

 

1b

 

 

 

 

Содержание KV 025 W 01

Страница 1: ...water and their surroundings due to the flue gas system and double or triple glazing used on the door Thanks to their modern design clear glass and the mirror effect of special reflective glass our in...

Страница 2: ...a Heat capacity 150 270 m3 Draft 12 Pa Flue gases 10 3 g s Average temperature of flue gases 159 C Efficiency 87 Complies with standards EN 13240 15a B VG DIN plus BimschV 1 2 Supplied accessories inc...

Страница 3: ...a Heat capacity 150 270 m3 Draft 12 Pa Flue gases 10 3 g s Average temperature of flue gases 159 C Efficiency 90 Complies with standards EN 13240 15a B VG DIN plus BimschV1 2 Supplied accessories incl...

Страница 4: ...l drawing of fireplace insert KV 025 W 01 with hot water exchanger C AI OUTLET VALVE G1 2 INSTALLATION DIMENSIONS SINK G1 2 160 OUTPUT FROM EXCHANGER G3 4 AFTERCOOLING LOOP G1 2 AIR OUTLET VALVE G1 2...

Страница 5: ...mal glazing Double glazing with reflective glass also maintains the maximum temperature in the fireplace which ensures ideal fuel combustion Combustion chamber The fireplace insert is equipped with a...

Страница 6: ...tter leaves the combustion chamber into the tube plate of the exchanger and the stream of air directed in the opposite direction to the blazing flames ensures mixing of the volatile flammable matter w...

Страница 7: ...jemn zasunout a pln vyjmout z kou ov komory vlo ky m je umo n no dokonal vy i t n horn sti v m n ku Cleaning Routine checks of the tube plate are possible from the inside of the combustion chamber of...

Страница 8: ...he top of the fireplace insert near the cleaning cover This arrangement not only provides comfortable access for maintenance of the fireplace insert itself but also for any necessary checks and mainte...

Страница 9: ...ireplace insert A larger amount of heat therefore remains in the hot water system The high quality insulation used is highly heat resistant approximately 1 000 C has low heat conductivity is safe to h...

Страница 10: ...al drawing of fireplace insert KV 025 W 02 with hot water exchanger SINK G1 2 160 OUTLET VALVE G 1 2 INSTALLATION DIMENSIONS OUTPUT FROM EXCHANGER G3 4 AFTERCOOLING LOOP G1 2 AIR OUTLET VALVE G1 2 EXC...

Страница 11: ...h minimizes heat radiation from the exchanger into the surroundings of the fireplace insert The ceiling of the exchanger is also fitted with a cover with thermal insulation in order to reduce heat rad...

Страница 12: ...ke flue and chimney is provided No structural changes or modifications of the appliance are permitted All local regulations including regulations relating to national and European norms must be observ...

Страница 13: ...here the installation of fuel appliances is not permitted Smoke flues can pass through walls If the wall is made of flammable structural materials or contains flammable components the smoke flue must...

Страница 14: ...must be conducted to the expected installation site with at least 2 m reserve i e to the fireplace installation site and to the auxiliary electric cabinet at the height of the switchboard approximatel...

Страница 15: ...urce thermostat in the accumulation tank the cable leads from the regulator to the combined thermostat installation site located in the upper part of the accumulation tank 1 x CYKY 3x1 5 alternatively...

Страница 16: ...must also be conducted to the switch board installation site 1 x CYKY 3x1 5 alternatively CYSY for connecting the fireplace pump the cable leads from the regulator to the installation site of the fir...

Страница 17: ...1 x 6A1f safety breaker for the regulator and other components of the heating system The selection and location of concrete cables must comply with valid regulations and standards Strips with electro...

Страница 18: ...17 5 CONNECTION DIAGRAM hydraulic connection of the fireplace exchanger...

Страница 19: ...ireplace insert i e 25mm deep and can be fitted with any image up to a size of 624 x 463 mm The genuine Romotop inspection door can be easily removed from its frame without the need to use any tools B...

Страница 20: ...e sided and four sided Both types are produced in three different depths 25 60 and 140 mm Frames are equipped with a fastening groove which enables the frame to be adjusted by 8 mm For our current off...

Страница 21: ...20 FRAME 025 LN 3S 60 2 0kg FRAME 025 LN 4S 60 2 7kg...

Страница 22: ...21 FRAME 025 LN 3S 140 3 4kg FRAME 025 LN 4S 140 4 7kg...

Страница 23: ...bustion with the saved program Optimization of the combustion process and based on an evaluation regulate the amount of air intake into the furnace It helps achieve a more even combustion process and...

Страница 24: ...erature in the exchanger by a capillary that is installed in the upper exchanger sink see diagram in chapter 6 A filter and ball valve must be installed on the water intake into the aftercooling valve...

Страница 25: ...visit http www romotop cz prislusenstvi Thermostatic mixing valve of the fireplace exchanger The thermostatic mixing valve is used to maintain the nominal temperature of return water to the fireplace...

Страница 26: ...Wilo Star RS 25 4 G6 4 is used for both hydraulic circuits It is a standard wet running circulation pump with 3 manually configurable speeds Circulation pumps are powered directly from regulator outpu...

Страница 27: ...ector can also be located vertically inclination of 90 e g on a facade Collector inclination must not be less than 20 When located on the roof we recommend placing the collector as close to the ridge...

Страница 28: ...ffer visit http www romotop cz prislusenstvi B Safety unit complying with CE and T V protects the installation against overpressure It is equipped with a safety 6 bar valve It is also equipped with a...

Страница 29: ...tion KK ball valve KK E service expansion valve VK draining valve AOV automatic air outlet valve EXP expansion tank PV safety valve TSV TV thermostatic mixing valve for HW TDV thermostatic aftercoolin...

Страница 30: ...29 Connection of DeltaSol M regulator option 1a outdoor sensor internal control unit regulator sensor thermostat EL cabinet reg M...

Страница 31: ...30 Diagram of electric connection with DeltaSol M regulator option 1a delayed relay min 30 s...

Страница 32: ...31 Connection of IS 07 SOL regulator option 1b outdoor sensor internal control unit regulator sensor thermostat reg IR07 EL cabinet...

Страница 33: ...32 Diagram for electric connection with IR 07 SOL regulator variant 1b...

Страница 34: ...quired temperature of the heating system T C Time hours KV 025 W 01 8 kW heating discharging time for accumulation tank with a volume of 500 L heating discharging time for accumulation tank with a vol...

Страница 35: ...here is no other withdrawal from the accumulation tank T C Time hours KV 025 W 02 9 kW heating discharging time for accumulation tank with a volume of 500 L heating discharging time for accumulation t...

Отзывы: