ELECTRICAL CONNECTION
The electrical connection must be carried out in
accordance with the current standards and laws in
force.
WARNING:
IF THE SUPPLY CORD IS DAMAGED, IT MUST
BE REPLACED BY THE MANUFACTURER, ITS
SERVICE AGENT OR SIMILARLY QUALIFIED
PERSONS IN ORDER TO AVOID A HAZARD.
Before connecting check that:
• The system and electrical sockets amperage is
adequate for the appliance maximum power (see
data label affixed on the back of the cooker).
• The socket or system has an effective earth
connection in accordance with current standards
and prescriptions of the law. All responsibility is
disclaimed if this is not complied with.
• The plug and socket or the multipolar switch must
be accessible after installation of the appliance.
•
The power cable must be laid so that no parts of it
ever reach a temperature of 75 °C.
• For connecting do not use, adapters or shunts
as they could cause false contacts resulting in
hazardous overheating.
INSTRUCTIONS FOR THE INSTALLER
Connect gas and electrical.
Before placing appliance in operation,
always check for gas leaks. This must
be performed by your dealer, a qualified
licensed plumber, or gas service company.
Connecting the power cord
IMPORTANT:
The wires in the mains lead
are colored and correspond to the following
prescription
L1
(phase 1) = BLACK
L2
(phase 2) = RED
N
(neutral) = WHITE
(Ground) = GREEN