![Roland Double Sheet Detector I100 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/roland/double-sheet-detector-i100/double-sheet-detector-i100_manual_1481827009.webp)
Manual
Double Sheet Detector R100 I100
for pairs of sensors
B0003308 / 1.4 /
13.02.2013
Technical data
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
9
2 Technical
data
Pos: 8 /Doppelblech/Geräte/R100/3 Technische DatenAuswertegerät I100 @ 0\mod_1184853225531_501.doc @ 4200 @
2.1 Control
unit
I100
Supply voltage
24 V DC / 110 mA
Power consumption
approx. 2 VA
Fuse
375 mA slow-blow size 1206 (SMD)
Power / switching indication
5 LEDs
Display
LCD display, 2 lines, 16 chars. each
Ambient temperature
0° - 50°C (32° - 122°F) during operation
Switching outputs 0-1-2 - Sheet
Opto coupler outputs, output sourcing (PNP)
Temperature depending drift of switching point
± 0,02 % / °C
Switching capacity
max. 50V, max. 10mA
Measurement period
The min. dwell time of the sheet between the sensors roughly
equals the sensor diameter in milliseconds, e.g. for S28 = 30 ms..
Enclosure
for DIN-rail mounting (EN50022, BS5584)
Class of protection I100 / I100-S / I100-IP65
IP00 / IP54 / IP65
Weight
approx. 0,2 kg (0.44 lbs)
Connections
Terminal block (I100 / I100-IP65) / Plug connection (I100-S)
Dimensions
125,4 × 103 × 38 mm (H × W × D)
12
5
,4
46
,5
103
fault
power
2 sheet
1 sheet
0 sheet
Fig. 1: Dimensions of I100 (for mounting on DIN-rail)
I100 abmessungen.wmf