Electrical installation
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
27
Sensors and cables
The sensors with pluggable cable
S…S
(transmitter) and
S…E
(receiver)
require the cables
SKOISS-GG
(transmitter) and.
SKOISE-GG
(receiver)
for operation with the I100-S.
For operating the sensors
S…
(transmitter) and
E…
(receiver) with firmly
attached cable and open wire ends at the
I100-S the plug
2277707
must be attached
at the transmitter cable and the plug
2277706
at the receiver cable, according
to the illustration below.
Both plugs can be ordered as set under
S0003517
, but can also be ordered
separately.
Fig. 15: Sensors and cables for I100-S
Sensor plug for receiver (2277706)
Pin 1
+V
in
wire colour: brown
Pin 3
-V
in
wire colour: white
3
1
view onto soldering side
enclosure
shield
transparent / green-yellow
Sensor plug for transmitter (2277707)
Pin 1
+12V
wire colour: brown
Pin 2
-12V
wire colour: white
Pin 3
common / GND
wire colour: green
3
2
1
view onto soldering side
enclosure
shield
transparent / green-yellow
Fig. 16: Allocation of sensor plugs for I100-S
Pos: 24 /Kapitelübersicht/07. Inbetriebnahme @ 0\mod_1121421999890_501.doc @ 511 @
SKOISS-GG
SKOISE-GG
2277707
2277706
Transmitter
S...S
Receiver
E...S
Transmitter
S...
Receiver
E...
I100-S
I100-S