2.3.1 Sensor
diagrams
The marked areas represent the working ranges of the sensors. For all combinations of sheet
thickness and sensor distance Ax within the range a double sheet condition will be securely
detected, if the switching thresholds are set “tight”. So it might be required to restrict the 1-sheet
detection range by changing the (factory-set) thresholds of 85% / 115% to approx. 95% / 105%.
The working ranges of the sensors depend very much on the material properties, they can deviate
from the sensor diagrams shown below.
0
2
4
6
8
10
12
14 15
S/E75
mm
Blechdicke
Sheet thickness
Ax
30
40
50
60
mm
AL
FE
mm
15
10
5
0
1
2
3
S/E28
mm
Blechdicke
Sheet thickness
Ax
AL
mm
10
20
30
40
1
2
3
4
5
6
0
S/E34
mm
Blechdicke
Sheet thickness
Ax
AL
FE
mm
10
20
30
40
2
4
6
8
10
0
S/E54
mm
Blechdicke
Sheet thickness
Ax
AL
FE
40
30
20
10
1
2
3
4
5
0
S/E34V
mm
mm
Blechdicke
Sheet thickness
Ax
Nicht magnetischer
Edelstahl (INOX)
Non-magnetic
Stainless steel (INOX)
0
1
1,5
2
2,5 mm
Blechdicke
Sheet thickness
20
30
40
mm
MSI18E/S (5KHz)
AL
Ax
Fig. 5: Sensor diagrams for S/E sensors and MSI18S/E sensors
ensordiagramme-S28-S75-deu-eng.wmf
Pos: 12 /Doppelblech/Kabel/S/E-Sensoren Kabelbelegung @ 0\mod_1185353919531_501.doc @ 4383 @ 33